6 Troubleshooting

POWER
AES/EBU
DATA
POWER
AES/EBU
DATA
POWER
AES/EBU
DATA
Additional Error Checking
The CobraNet Setup window (Section 5.2.1) describes a group of error indicators that show errors associated with
CobraNet status.
page 70
CONDITION: Power indicator is
off.
POSSIBLE REASON
The unit has lost AC power.
The unit is not plugged into the power
receptacle.
CONDITION: AES/EBU indica-
tor is off, even though the unit is
being fed an AES/EBU signal.
POSSIBLE REASON
The AES input has not been selected,
either from the front panel or in IQwic
software.
CONDITION: Data indicator is
off, even though the unit is con-
nected to a network.
POSSIBLE REASON:
Unit is not receiving data. Check net-
work addressing of all components.
Note: Data indicator flashes only when
the amplifier is polled for data, or is
polled to see whether it is online.
INPUT
4
6
1
2
3
5
7
OUTPUT
4
6
1
2
3
5
7
INPUT
1
2
3
4
5
6
7
OUTPUT
1
2
3
4
5
6
7
Internal errors are automatically displayed on the LCD Display Screen. If an error is displayed, call Tech Support at
Crown and provide them the error number.
DBC Network Bridge
CONDITION: Input LEDs are off.
POSSIBLE REASON:
8
The unit is not receiving an analog or dig-
ital (CobraNet) input signal. Check
cables, cable wiring, and connections.
The source feeding the DBC Network
Bridge is not producing a signal. Check
8
its output signal.
The cable between the signal source and
the DBC Network Bridge is defective.
Replace or repair it.
Addressing has not been set up correctly.
Please review Section 1.2.
CONDITION: Output LEDs are off
but Input LEDs are flashing.
POSSIBLE REASON:
8
In IQwic, Signal Path tab, Cinema Sur-
round form, the output path has not been
set up.
8
Operation Manual