Crown DBC NETWORK BRIDGE 137769-3 Operation Manual page 51

Crown network hardware user manual
Table of Contents

Advertisement

DBC Network Bridge
5 Advanced Operation
Control Port: Condition Logic Setup Window
To open the Condition Logic Setup window (Figure 5.9), press the
1
9
Edit Mapped Conditions button in the Control Port window.
2
1. Condition
Allows up to 64 different binary combinations of pin states. Up to eight
inputs are allowed in any state, giving up to 255 different combinations
7
for each of the the 64 configurations.
3
2. Name
Naming convenience for the configuration. 64 names are available.
4
3. Include
Of the eight bits available to read, Include instructs the unit which of
the eight to include in the binary scheme.
5
4. Pin Combinations
Assigns included pins in selected states; it can be either a true or false
action. When true, do X; when false, do Y.
5 and 6. Pin Combinations and Resulting State Field
Allows you to assign up to 255 different combinations of pin states, and
assign that combination to be either true or false.
7.Conditions
A numeric view of #3 above.
8. Control Port Simulation
8
An area that allows you to set the pin states on the control port to either
high or low to test assigned logic for desired operation.
6
9. Edit Condition Actions
Press this button to go to the Control Port Assignment Dialog
(described on the previous two pages).
Figure 5.9 Condition Logic Setup Window