Optimus COMPACT Installation And Operating Instructions Manual page 26

Modular audio matrix with ip connection
Hide thumbs Also See for COMPACT:
Table of Contents

Advertisement

Available languages

Available languages

COMPONENT
GENERATING
THE
TYPE OF ALARM
ALARM
C ["n":"p" ]
CONFIGURATION
ERROR
(n= Number of
slave, id.)
If the value is 0,
the unit is a
COMPACT)
(p= Slot occupied by
the card)
"ZONE NAME"
LZ LINE ERROR
"ZONE NAME"
HZ LINE ERROR
"ZONE NAME"
AMPLIFIER ERROR
"ZONE NAME"
SHORT LINE ERROR
"ZONE NAME"
OPEN LINE ERROR
COMPACT version 5.2.002 ENG
COMPACT
4ETH
DESCRIPTION
The unit "n" incorporates a card in slot
"p" that does not appear in the
configurations of the installation.
When monitoring the speaker line of the
indicated zone, the system detects a low
impedance error.
When monitoring the speaker line of the
indicated zone, the system detects a
high impedance error.
Zone amplification error
When monitoring the speaker line of the
indicated zone, the system detects a
short-circuit in the line.
When monitoring the speaker line of the
indicated zone, the system detects an
open line error.
Modular audio matrix
with IP connection
RECOVERY
Use the Call Point software to add the
unit to the installation tree.
or
remove the card from the COMPACT or
COMPACT-E chassis
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the tolerance margin for
detecting the error.
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the
tolerance margin for
detecting the error.
Check the operation of the amplifier
Inspect that speaker line.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the tolerance margin for
detecting the error.
Inspect that speaker line.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the tolerance margin for
detecting the error.