Period (1)
Yearly
"
"
Yearly
"
"
"
"
"
"
"
"
"
"
"
(1) : whichever comes first.
(2) : more frequently in a dusty environment
(3) : The indicated oil exchange intervals are valid for standard operating conditions (see section
Reference conditions and
Exposure of the compressor to external pollutants or operation at high humidity combined with low duty
cycles may require a shorter oil exchange interval. Contact Atlas Copco if in doubt.
Important
58
Running
Action
hours (1)
Replace the oil filter and oil separator
2000
2000 (3)
If Roto-Inject Fluid NDURANCE is used, change the oil.
2000 (2)
Replace the air filter.
4000
Replace the oil filter.
4000 (3)
If Roto Synthetic Fluid ULTRA is used, change the oil.
4000 (2)
Replace the air filter.
4000 (2)
Replace the oil separator.
4000
For compressors with PDX filter, replace the filter.
Replace the belts.
4000
--
Have the safety valve tested.
Have the operation of sensors, electrical interlockings and
"
components checked.
"
Have the temperature shut-down switch tested.
Inspect the air receiver.
The air receiver must no longer be used and must be replaced if the
--
wall thickness is less than the minimum value, specified in the
technical documentation of the air receiver.
8000
Service the instrument block: Thermostatic and MPV kit.
8000
Check and clean the inlet valve. Use the unloader kit.
limitations) and nominal operating pressure (see section
Always consult Atlas Copco if a service timer setting has to be changed.
For the change interval of oil and oil filter in extreme conditions, consult your Atlas
Copco Customer Centre.
Any leakage should be attended to immediately. Damaged hoses or flexible joints
must be replaced.
Instruction book
Compressor
data).
9095 1100 81

Advertisement

Table of Contents
loading

This manual is also suitable for:

G 22

Table of Contents