S T O R A G E
Conservation / storage of the compressor
If the compressor unit is not to be used for an extended period of time, we recommend to
carry out the following work before storage time:
Run the compressor at 200 bar filling pressure for approximately ten minutes
(control the flow with the filling valve to maintain constant pressure).
Replace compressor oil, open filling valve(s) and run compressor for a few minutes.
Stop compressor and open drain valves (depending on the compressor type, this may
happens automatically). Remove top cap of final filter housing: clean threat, grease o-ring.
and threat with a food grade grease or silicone grease. Close filter housing.
Remove intake filter cartridge and undo intake pipes on all valve heads.
Start compressor unit. Spray a few drops of compressor oil into intake connectors.
Stop compressor unit and insert intake filter cartridge. Bring intake pipes back in position and
fix connections and nuts. Close filling- and drain valves.
Store the compressor in a cool dry place free from dust and contamination.
A dust cover is recommended as long as condensation can be avoided.
If compressor unit should be stored for a period of more than one year, an oil change is
strongly recommended before it's been re-used.
Fuel driven units only: fill up fuel tank to top level to avoid corrosion.
De-conservation, commissioning
After the compressor has been stored, the following steps are to be taken:
If compressor hasn't been used for longer than 12 months, we strongly recommend an oil
change before any use.
Replace intake filter cartridge and check oil level.
Clean compressor unit, check for foreign objects. Check condition and tension of V-belts,
replace if necessary. Check condition of filling hoses, replace if necessary.
Secure hoses against whipping and open filling valves and run compressor for approximately
10 minutes.
Check condition of final filter cartridge, replace if necessary.
Close filling valves and run compressor up to final pressure.
Check safety valve relief pressure of final stage and/or pressure switch setting.
Check all connections and pipe work for leaks.
Once all above steps are completed, compressor unit is now ready for use.