L&W SC-600 ES Operating Instructions Manual page 42

Breathing air compressor
Table of Contents

Advertisement

M A I N T E N A N C E A N D S E R V I C E
Annually
Maintenance work
Oil change, if less than 1000 operating hours
Check V-belt tension and condition
Check opening pressure of final safety valve
Clean coolers
Clean all oil/water separators, if less than 500
operating hours
Service intake filter (depends on condition - if
less than 500 operating hours)
Check all connections for leakage
Every 500 operating hours
Maintenance work
Change intake filter
Check pressure maintaining/non-return valve
Check V-belt tension and condition
LW SC-600 ES / LW SC-680 ES / LW SC-750 ES
Version: 01.01.2023
Type
Quantity
-
LW SC-600 / 680 ES II
(50Hz)
LW SC-750 ES II (50Hz)
-
-
-
-
-
Type
Quantity
-
-
LW SC-600 / 680 ES II
(50Hz)
LW SC-750 ES II
Order No.
2,5
000001
2
001452
2
001413
-
-
-
-
-
-
-
-
-
-
Order No.
1
000170
-
-
2
001452
2
001413