L&W SC-600 ES Operating Instructions Manual page 44

Breathing air compressor
Table of Contents

Advertisement

M A I N T E N A N C E A N D S E R V I C E
Every 2000 operating hours
Maintenance work
Replace all inlet and outlet valves incl. gaskets
Every 4000 operating hours (Latest in 10 years)
Maintenance work
Replace all o-rings and gaskets of
1st, 2nd, 3rd and 4th stage
Replace shaft seal
Replace needle bearings for conrod
2nd, 3rd and 4th stage
CU-Ring (Ø10 x 16 x 2mm)
LW SC-600 ES / LW SC-680 ES / LW SC-750 ES
Version: 01.01.2023
Type
Quantity
1st stage
2nd stage
3rd stage
4th stage
Upper gasket 1st
Upper gasket 2nd
Lower gasket 1st
Lower gasket 2nd
Type
Quantity
O-ring
gasket
o-ring
-
-
-
Order No.
1
000369
1
000256
1
010346
1
010347
1
000349
1
000254
1
000350
1
003492
Order No.
1
000409
3
000240
2
001274
1
000244
3
003281
16
001323
Page A - 42
A

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Sc-680 esSc-750 es

Table of Contents