R E M E D Y I N G F A U L T S
Compressor does not reach final pressure
Cause of fault
Connections leaking
Final pressure safety valve leaking
Pipes / heat exchanger damaged
Condensate drain valves leaking
Final pressure switch stop unit
Piston of pneumatic condensate valve seezed
Strong Compressor Vibration
Cause of fault
V-belt tension too loose
Drive motor / Compressor unit loosely
Anti vibration mounts used up
Ground not levelled
Flow Rate too Low
Cause of fault
Inlet and outlet valves contaminated / defective
Cylinder(s), piston(s) or piston ring(s) used up
V-belt slips
See chapter "Final pressure can not be reached"
LW SC-600 ES / LW SC-680 ES / LW SC-750 ES
Version: 01.01.2023
Remedy
Retighten or clean/replace if necessary
Replace
Replace
Unscrew valves, check sealing surfaces, clean,
replace if necessary
Verify settings, replace if necessary
Clean pneumatic condensate valve and restore
function, check/replace o-rings, replace valve
completely if necessary
Remedy
Tension V-belt
Retighten mounting screws
Replace
Ensure a solid and level ground
Remedy
Clean, replace if necessary
Replace
Tension V-belt
See chapter "Final pressure can not be reached"