Siemens WT43N203FG Manual page 41

Table of Contents

Advertisement

Disturbance
Condensation in
condensation container
ter even though water drains
running hose connected
is closed.
Program starts
not.
Change program duration
changes during drying.
Pumping noise.
Whirring noise.
Drying time is too
long.
Cause and troubleshooting
A residual amount of condensation may remain in
the condensation container.
No error - no action necessary.
Water drain hose is not connected correctly.
Make sure the water drain hose is connected
correctly.
→ "Connecting the water drain hose", page 14
Parental controls are activated.
→ ""Deactivate parental controls", page 33
Start/Pauze / Départ/Breakwas not pressed.
PressStart/Pauze / Départ/Pause .
No program set.
→ "Setting the program", page 29 .
1.
→ "Start the program", page 30 .
2.
Program flow is electronically optimized. This can lead
to a change in the program duration.
No error - no action necessary.
Condensation water pump active.
No error - normal operating noise.
Compressor ventilation active.
No error - normal operating noise.
Lint filter is dirty.
"Cleaning the lint filter", page 31
Ambient temperature is higher than 30 °C.
Make sure the ambient temperature is below 30°C.
Ambient temperature is lower than 15°C.
Make sure the ambient temperature is above 15°C.
Insufficient air circulation where the device is
installed.
Ventilate the installation location of the device.
The ventilation opening of the device is blocked.
Make sure that the ventilation opening of the
device is kept clear.
Heat exchanger is contaminated.
Open ground unit.
1.
"Open the ground unit", page 35 .
Troubleshootingde
41

Advertisement

Table of Contents
loading

Table of Contents