Balboa CLIM8ZONE II User And Service Manual page 15

Inverter heat pump for spas
Hide thumbs Also See for CLIM8ZONE II:

Advertisement

E12
Exhaust too high
protection
E15
Inlet water temp. Error
E16
Outer coil pipe temp.
Error
E18
Exhaust gas temp. Error
E20
Abnormal protection of
frequency conversion
module
E21
Ambient temp. Error
E27
Outlet temperature fault
E29
Return gas temp. Error
E46
DC Fan Error
E20 fault will display the following error codes at the same time, the error codes will switch every 3 seconds. Among
them, error codes 1-128 are displayed in priority.
When error codes 1-128 don't appear, then error codes 257-384 can show.
If two or more error codes appear at the same time, then display error codes accumulation.
For example, 16 and 32 occur at the same time, display 48.
Error
name
Code
1
IPM Over-current
damaged
1. Less refrigerant or leakage
2. The system blocked
3. Compressor refrigerant oil is
insufficient
4. The resistance value of the
exhaust probe is offset, and the
inlet temperature probe is
dropped
The sensor plug is in poor contact
or off, or the sensor is damaged
The sensor plug is in poor contact
or off, or the sensor is damaged
The sensor plug is in poor contact
or off, or the sensor is damaged
IPM module internal fault, check
related problems according to the
attached table
The sensor plug is in poor contact
or off, or the sensor is damaged
The sensor plug is in poor contact
or off, or the sensor is damaged
The sensor plug is in poor contact
or off, or the sensor is damaged
1.Dc fan failure
2.Plug is in poor contact or off
description
1. The IPM overloaded or
overheated
2.
The
U,V,W
short-circuited
3. The IPM module fault
4. The compressor damaged
1. Refill the refrigerant
2. Replace the filter
3. Add refrigerant oil to the
compressor
4. Replace the exhaust probe
and reconnect the water inlet
temperature probe
Check and replace the water
inlet temperature sensor(T2
sensor)
Check and replace the coil pipe
temperature sensor(T3)
Check and replace the exhaust
gas temperature sensor(T1)
Check and replace the ambient
temperature sensor(T4)
Check and replace the water
outlet temperature sensor(T6)
Check and replace the suction
gas sensor(T5)
1. Replace the DC fan
2. Reconnect cables to the DC
fan
Solution suggestion
1
Ensure
temperature,
driver
temperature, water flow, etc. are
within the operating range of
the unit;
2. Use a multimeter to measure
that
the
ring
water
15

Advertisement