Balboa CLIM8ZONE II User And Service Manual

Balboa CLIM8ZONE II User And Service Manual

Spa heat pump
Hide thumbs Also See for CLIM8ZONE II:

Advertisement

Quick Links

CLIM8ZONE II – 120V
SPA HEAT PUMP
User and Service manual

Advertisement

Table of Contents
loading

Summary of Contents for Balboa CLIM8ZONE II

  • Page 1 CLIM8ZONE II – 120V SPA HEAT PUMP User and Service manual...
  • Page 2: Important Safety Instructions

    Spa Heat Pump User and Service Manual (standalone mode) INDEX 1. Specifications 2. Dimension 3. Installation and connections 4. Electrical Wiring 5. Controller Panel Operation 6. Wifi Connection and Operation 7. Maintenance IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS This manual contains all the necessary information for the use and installation of your heat pump 1.
  • Page 3 DANGERS: Disregarding the following instructions will result in serious injury or even death The heat pump utilizes high voltage and rotating equipment, so use caution when servicing.  Always turn off the power supply before opening the cabinet to access the interior of the heat pump, ...
  • Page 4 WARNING: Make sure the switch is turned to the power off position before install the heat pump or maintenance the heat pump WARNING: To reduce the risk of injury, this appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety at all times.
  • Page 5 DANGER : Risk of Electric Shock. Install at least 5 feet (1.5 m) from inside wall of hot tub or spa using nonmetallic plumbing. DANGER – Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum 6 AWG (13.3 mm2) solid copper conductor to the wire connector on the terminal box that is provided for this purpose.
  • Page 6: Specifications

    Caution:The manufacturer is not responsible for any radio or tv interference causeld by unauthorized modifications or change to this equi pment. such modifications or change could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 7: Technical Data

    1.1 Technical data 120V Clim8zone II – Compact Heat Pump for Spas Product model C8ZII-120V Advised maximum spa volume(gallons / with cover) Heating operating ambient temperature range(°F) 23 ~109 50~104 Cooling operating ambient temperature range(°F) Operating water temperature(℃) heating 15~40 Operating water temperature(℃) cooling...
  • Page 8 unit: mm 2.2 Exploded View...
  • Page 10: Installation And Connections

    3. Installation and connections 3.1 Notes The factory supplies only the heat pump. All other components must be provided by the user or the installer. Install a bypass if the water flow from the water pump is more than 20% greater than the allowable flow through the heat exchanger of the heat pump.
  • Page 11 3.4 Plumbing Connections 3.4.1 Plumbing diagram 3.4.2 Check-valve installation (recommended) If automatic dosing equipment for chlorine and acidity (pH) is used, it is essential to protect the heat pump against excessively high chemical concentrations which may corrode the heat exchanger. For this reason, equipment of this sort must always be fitted in the piping on the downstream side of the heat pump, and it is recommended to install a check- valve to prevent reverse flow in the absence of water circulation.
  • Page 12: Electrical Wiring

    The amount of condensation may be as much as several litters per hour at high relative humidity. This is condensation water, not leaked water. 4. Electrical Wiring 4.1 CLIM8ZONE II HEAT PUMP WIRING DIADRAM...
  • Page 13 5. Controller Panel Operation 5.1 Controller Panel Display: 5.2 Button Descriptions: Description Turn ON/OFF the controller panel Increase the setting values. Decrease the setting values. Change modes. Red LED On Heating mode Green LED On Cooling mode The red light and the green light on for 3 seconds at the same Automatic heating...
  • Page 14 0~1590 Unit operation mode 0:AP* mode/1: BP** mode * AP = Standalone; ** BP = Integrated with Balboa BP Spa Controller 7. Change Unit operation mode Long press two buttons for 15 seconds at the same time to switch between AP and BP modes;...
  • Page 15  Press button to advance to the second password digit and enter "8" by pressing buttons,  Press button to submit the password. After entering, select or change parameters by using buttons  Press button to make entry changes or confirm and return to the viewing status. System parameter table Parameter Parameter name...
  • Page 16 Main valve set exhaust gas 70-125 Main valve defrosting opening 2-45 degree Minimum opening degree of 5-15 the main valve Expansion valve mode 0 Manual / 1 Automatic Manual steps of the main valve 2-45 Cooling opening degree of the 2-45 main valve 5.5.
  • Page 17 2. Check the frequency conversion board damaged communication cables module (alarm when 2. The connector of the between the main board and communication is communication cable between driver board disconnected between the main board and the driver 3. Replace the external board and drive board is in poor contact or falls communication cable...
  • Page 18 If two or more error codes appear at the same time, then display error codes accumulation. For example, 16 and 32 occur at the same time, display 48 Error name description Solution suggestion Code IPM Over-current 1. The IPM overloaded or Ensure that ring...
  • Page 19 temperature 2. The air duct is blocked 2. Ensure proper ventilation Radiator temperature 1. The heat sink sensor is 1. Replace the frequency error short-circuited or open conversion module 2. Heat sink fouling 2. Remove dust and scale 3. The ambient temperature from the heat sink too high Lower...
  • Page 20 Power up the Clim8zone II.  The Clim8zone II will automatically go to paring mode for 10 minutes. Please pair the Clim8zone with you mobile device within this 10 minutes time frame. While in paring mode, the word “nEt” will be flashing on the front panel and stay flashing until paring is done.
  • Page 21  The interface will show “Discovering devices…”. Click “Add” to enter “Add Device” interface. (Note: I can also choose to add manually, by clicking on “Large Home Appliances”, then choose “Water Heater (Wi-Fi)”  Select the same 2.4GHz Wifi network with your mobile device and enter password. ...
  • Page 22 (NOTE: it may take several times to pair depending on the strength of your Wi-Fi signal. Retry as needed) 6.3. App operation 6.3.1. Interface Introduction  After the device is successfully added, click “Pool Heat Pump” (your app may show different name) in “All Devices”...
  • Page 23 6.3.2. Icons  Change device name Select device installation location Check network status Add shared users Create device group View device information  Return to previous page  Turn the Clim8zone II on ON/OFF,  Set Heating or Cooling mode...
  • Page 24  View device status data  Set Heating / Cooling temperatures Set timers turn device ON/OFF 6.3.3. Sharing device: The “Share Device” feature in the Smart Life app allows you to share access to your heat pump with other Smart Life app users.
  • Page 25: Maintenance

    Press " " and " " for about 5 seconds at the same time, after hear a buzzer to enter the pairing mode, and then repeat the above connection operations. 7. Maintenance Maintaining your spa heat pump is crucial to ensure its optimal performance and longevity. Here are some essential maintenance instructions for your spa heat pump: 1.

Table of Contents