Download Print this page

Balboa CLIM8ZONE II User And Service Manual page 10

Inverter heat pump for spas
Hide thumbs Also See for CLIM8ZONE II:

Advertisement

3. Press the
Power button on front panel for 2 seconds.
4. Set the unit to Heat or Cool mode by pressing the
Mode button. Heating = Red LED on. Cooling = Green LED on.
5. Set temperature by pressing
Up or
Down buttons.
6. The unit will start up after the time delay expires.
7. After a few minutes, air will be blowing out of the fan grill.
8. Complete!
Time delay - The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive contact
wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will trigger this time
delay and prevent the unit from restarting immediately. Additional power interruptions during this delay period do not
affect the 3-minute duration of the delay.
3.7 Condensation
In heat mode, the air drawn into the heat pump is greatly cooled by the operation of the heat pump for heating the spa
water, which may cause condensation on the fins of the evaporator. The amount of condensation may be as much as
several litters per hour at high relative humidity. This is condensation water, not leaked water.
4. Electrical Wiring
4.1 CLIM8ZONE II HEAT PUMP WIRING DIADRAM
10