Push th
e
TRIG V
IEW
button and
hold It
in.
Us
e t
he
DELAY TIME POSITION
con
t rol
to
move
the
r
efere nc e
po int to
th e center ho ri zo n tal
q
raticufe li
ne
(see
Fig.
13.
Po int
A
).
Use the A
LT D
ELAY
con
tra l to move the ti
me-
measu re men t p
o int to th
e
ce
nte r h
or izonta l q
raticute
nne
on
th
e
next cy cle (see Fig
13, Poin
t
B)
.
Veri fy th
e readout
is 16 .49
to 16.84 a
nd
the rns lamp is
lit
I
,
~
J.
<a
~
~
1\
I
,
1
"
I
0
,
I
1
73a-1 5
f
ig.
13. OM44 timing ch
eCk.
E
xt ernal
H
oriz ontal G
ain
Check
(It
X-Y
o
p e rati o n is
to be
us
ed .)
Use steps
1
through
3
o
f
th e Bas
ic
Osci ll oscope
Di
spl ay s procedure
for
obtain
ing
a
No rma l
Sw ee p D
isp lay o
f the
c
a
ibrator
sq
uare-wa ve
vo
ltag e wa
vef orm ; then, set
the
TIME/DIV
sw
it ch to X-Y
o
With th e ca
lib rat or sig nal c
o n nec ted to the
C
H 1 OR X
input conn
ec to r a
nd
th
e
CH 1
VOL
TS
/DIV
switch set
to
50
mV, the
crt
d
ispl
ay
should
be two
dots separated
h
orizo ntally by 5.75 to
6
.25
divisions.
PEA K-T O -PEA K
VOLTAGE
ME
ASUREMENTS-
A C
Obtain
a No
rm
a l
Display
,
Make
sure the V
AR
VOL TS
/DtV
control is in the
calibrated
d
etent.
Vertically
position the d
isplay so
the lowe
r
portion coincides w
ith
a
horizontal
qratrcute
line
(see Fig, 14
.
Poi
nt
A)
Horizonta lly
posit ion
the display so one
ct
th
e upper pea
ks
co
incides
with
the
cen
te r
ve
rti ca l
g
raticule
line
(see Fig , 14
.
Poin
t B
).
Measure the
vertical deflection '
ro m peak-
to -peak
(Po i
nt
A to Point
B)
@
475
/D
M 44 Ope rato rs
31
M
u lt iply the v
ert ic al def
lect
ion
just measured by the
VOL
T
S/DIV
switch sett
ing
A
lso
in
cl ude
the atte
nuation
fact or
of the pr
obe if
th
e
pr
obe does not
have a scal
e-
factor sw
itching c
on nec to
r.
Substituting
the given values'
Example :
The
peak-to-peak
measured
is 4.6 d
ivis io ns
(see
Fig
sw
itc h
sett
ing
of
.5.
POSITION
TO
CEN TE R LI N E
'
.
B
,.
l
~
-
-
~
--I
1
\
~(A
II
,
I
I
,
'I
VERTICA
L
~
/
DEFLECT ION
. .
J
,
"
'J
!L
0
MEASURE
AMPLITUOE
FRO
MATDB
(
1 7 3 8 16 12 0 3 9
·
1 5
Fig
. 14.
Peak -la -peak vol
tage
o
f
a
.....
ave
form.
Usi
ng
th
e formu la :
Volts
Peak-t
o-peak
vertic
al
deflection
(d ivisio n s)
vertical
deflection
14) with a VOLT
SIDIV
X VO
LTS/DIV
se
tting
NOT
E
If 'he ampJirude measurement
IS
cnucet or if the
tra
ce
is
thick
as a
result of hum
and'
o r none on Ihe
Signa
l,
a
more accurate measurement
c
an be
ob·
tetnea by measur,ng from the
top o
t a peak 10 the top
of a 'rIal/ey. This
Will
soc
rrecr
the trace thic
kness
from
the
measurement.
Volts
Peak-to-Peak
=
46 X 0,5 V
=
2.3 valls.
INSTANTANEOUS VOLTAGE
MEASUREMENTS-DC
Ob
tain
a
Normal
Display
,
Make
sure
the VAR
ValT
Si
O IV con
trol
is in the ca
librated
detent.
32
47
5/0M
44
Operators
@