7.3.3.
Creating the I/O Table
Create the I/O table for PLC.
1
If the operating mode of PLC is
Run Mode or Monitor Mode,
change it to Program Mode by
following the steps below.
(1)Select Operating Mode -
Program from the PLC Menu
in CX-Programmer.
(2)The confirmation dialog box
on the right is displayed.
Confirm that there is no
problem, and click Yes.
*Refer to Additional Information
on the previous page for the
settings concerning the dialog
display.
(3)Check that Stop/Program
Mode is displayed on the right
of the PLC model in the
project workspace of
CX-Programmer.
2
Select Edit - I/O Table and Unit
Setup from the PLC Menu in
CX-Programmer.
The PLC IO Table Window is
displayed.
Precautions for Correct Use
The PLC is reset after creating and transferring the I/O table in step 3 and subsequent steps.
Always confirm safety before creating and transferring the I/O table.
7.Serial Communications Connection Procedure
23