DIMENSIONS:
Models
IVTP-1M-FL
IVTP-3M-FL
IVTP-2M-FL
IVTP-4M-FL
IVTP-5M-FL IVTP-6M-FL
IVTP-7M-FL IVTP-8T-FL

HYDRAULIC CONNECTIONS:

– Water quality necessary for this device: NF-EN-16713-3
– The HP is compatible with all types of water treatment. The HP must imperatively be connected by a PVC pipe of Ø 50mm to the swimming pool' s hydraulic
circuit, after the filter and before the treatment system, regardless of its type (Cl, pH, Br metering pumps and/or electrolyser).
– Follow the hydraulic connection order (blue = water in, red = water out)
– A bypass must be installed to facilitate work on the HP.
– Before connecting the PVC pipes to the HP, make sure the circuit is clean of any work residue (stone, soil, etc.).
Connection of the condensate evacuation pack:
During operations, the HP is subject to a condensation phenomenon. This translates into a water flow, which can be more or less important depending on the
degree of humidity. To channel this flow, which can represent several litres of water per day, we recommend you install the provided condensate evacuation pack
and connect it to a suitable water evacuation circuit.
Provided connections
(ø 50mm)
HP
Condensate evacuation
B
D
A
B
657 mm
977 mm
756 mm
1076 mm
922 mm
1175 mm
Bypass
Open valve
Half-open valve
Closed valve
C
C
D
397 mm
510 mm
450 mm
669 mm
508 mm
669 mm
Bypass valve
(adjustment)
pH +/-
E
F
410 mm
103 mm
465 mm
92 mm
485 mm
92 mm
Water treatment (disinfection, pH correction)
located after the HP
FROM THE SWIMMING POOL
TOWARDS THE SWIMMING POOL
G
290 mm
320 mm
430 mm
5