  • Page 1 NEXCOM International Co., Ltd. Intelligent Platform & Services Business Unit Visual Edge Compter NDiS B560-Q User Manual NEXCOM International Co., Ltd. www.nexcom.com Published February 2024...
  • Page 2: Table Of Contents

    External I/O Interfaces - Rear Panel.............15 Rear Panel ...................2 USB 3.1 Ports .................15 Hardware Specifications ................3 USB3.1 Ports ..................15 Mechanical Dimensions ................5 DC In Connector ................16 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 3 NGFF Key B Connector ..............30 SATA And RST Configuration .............71 Block Diagram ..................31 HD Audio Configuration ..............72 EDID Mode Control ................73 Security .....................73 Boot ....................74 Save & Exit ..................75 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 4: Preface

    No describes how to keep the system CE compliant. part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from NEXCOM Declaration of Conformity International Co., Ltd.
  • Page 5: Rohs Compliance

    (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) < 0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or 1,000ppm. In order to meet the RoHS compliant directives, NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products.
  • Page 6: Warranty And Rma

    “NEXCOM RMA Service Form” for the RMA number apply process. ▪ If RMA goods can not be repaired, NEXCOM will return it to the customer without any charge. ▪ Customers can send back the faulty products with or without accessories (manuals, cable, etc.) and any components from the card, such as CPU...
  • Page 7 ESD workstation. If no such station is available, you can provide some ESD protection by wearing an antistatic wrist strap and attaching it to a metal part of the computer chassis. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 8: Safety Information

    ▪ The instructions shall require connection of the equipment protective earthing conductor to the installation protective earthing conductor (for example, by means of a power cord connected to a socket-outlet with earthing connection). viii Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 9: Safety Precautions

    12Vdc, 8A or 8.33A minimum, Tma 40 degree power source to avoid damage by transient overvoltage. C minimum and altitude 2000m. If further assistance is needed, please contact NEXCOM for further information. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 10: Technical Support And Assistance

    Preface Technical Support and Assistance Conventions Used in this Manual 1. For the most updated information of NEXCOM products, visit NEXCOM’s Warning: website at www.nexcom.com. Information about certain situations, which if not observed, can cause personal injury. This will prevent injury to yourself 2.
  • Page 11: Global Service Contact Information

    Fax: +886-2-8226-7782 Shanghai, 201108, China Taichung City, 406, Taiwan, R.O.C. Email: sales@nexcom.com.tw Tel: +86-21-5278-5868 Tel: +886-4-2249-1179 www.nexcom.com.tw Fax: +86-21-3251-6358 Fax: +886-4-2249-1172 Email: sales@nexaiot.com Email: sales@nexcom.cn www.nexaiot.com www.nexcom.cn Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 12 9F, Tamachi Hara Bldg., LongGang District, 4-11-5, Shiba Minato-ku, ShenZhen, 518112, China Tokyo, 108-0014, Japan Tel: +86-755-8364-7768 Tel: +81-3-5419-7830 Fax: +86-755-8364-7738 Fax: +81-3-5419-7832 Email: steveyang@nexcom.com.tw Email: sales@nexcom-jp.com www.nexcom.cn www.nexcom-jp.com Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 13: Package Contents

    Preface Package Contents Before continuing, verify that the NDiS B560-Q package that you received is complete. Your package should have all the items listed in the following table. Item Part Number Name 10W00B56007X0 NDiS B560-Q System 5060200531X00 Thermal Pad E-LIN 50x25x1.0mm K=4.2W/mk PK404 (for M.2) 5060200579X00 Thermal Pad E-LIN 50x25x2mm K=4.2 W/mk PK404+9448 (for M.2)
  • Page 14: Ordering Information

    Preface Ordering Information The following information below provides ordering information for NDiS B560-Q. NDiS B560-Q (P/N: 10W00B56007X0) - 9th and 8th generation Intel Core™ processor (up to 35W) fanless system ® - Intel ® PCH Q370 chipset Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved.
  • Page 15: Chapter 1: Product Introduction

    In ▪ Fanless design addition, the NDiS B560-Q can be operated in an extended operating temperature range between -20 to 60°C, with three 4K2K independent ▪ Support a wide temperature range of -20 to 60°C display output and rich connectives including Wi-Fi and 4G, 5G support.
  • Page 16: Physical Features

    Physical Features Front Panel Rear Panel Power Button HDMI2 LAN LAN Power COM4 COM3 COM2 COM1 USB 3.0 HDMI1 HDMI3 Reset USB 3.0 DC in Mic-In Line-out Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 17: Hardware Specifications

    – COM1: RS232/422/485 ▪ 238 mm (W) x 192 mm (D) x 67.29 mm(H) (9.4” x 7.6” x 2.6”) – COM2~4: RS232 ▪ 2 x Antenna hole Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 18 ▪ FCC Class A (Part 15B) Operating System ▪ Windows 10/11/Linux Package Information ▪ 1 pc/carton ▪ G.W: 5kgs ▪ Dimension: 420 x 275 x 127mm Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 19: Mechanical Dimensions

    Chapter 1: Product Introduction Mechanical Dimensions 67.30 238.00 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 20: Chapter 2: Jumpers And Connectors

    Static electricity can damage many of the electronic ▪ Use correct screws and do not over tighten screws. components. Humid environments tend to have less static electricity than Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 21: Locations Of The Jumpers And Connectors For Ndib B560-Q

    Locations of the Jumpers and Connectors for NDiB B560-Q NDiB B560-Q The following figure are the top and bottom view of the NDiB B560-Q, which is the main board used in the NDiS B560-Q. It shows the locations of the jumpers and connectors. DCIN1 CN2 CN1...
  • Page 22: Bottom View

    Chapter 2: Jumpers and Connectors Bottom View C608 C621 M2B_42 DIMM1 M2B_52 SIM1 SIM1 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 23: Jumper Settings

    (on) and open (off). Two-Pin Jumpers: Open (Left) and Short (Right) Three-Pin Jumpers: Pins 1 and 2 are Short Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 24: Jumper And Dip Switch Settings

    PBT_SW CLRCMOS ATATX AT/ATX Mode 1-2 On Normal 1-2 On AT Mode 2-3 On Clear CMOS 2-3 On ATX Mode 1-2 On: default 2-3 On: default Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 25: Connector Pin Definitions

    Connector location: LED4 Connector location: SW2 Power Definition Definition Definition Definition H_PWRBTN#_M POWER_LED LED_PWRN H_PWRBTN#_M HD_LED HD_LEDN PWRLED_N PWRLED_P Power LED Definition LEDs LED Definition Blue Power Green Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 26: Com 1 Port

    COM2DSRL COM1TXD COM1DTRL COM2RTSL COM2CTSL COM1DSRL COM2RIL COM1RTSL COM1CTSL Front_GND Front_GND COM1RIL Front_GND Front_GND RS422 COM1DCDL COM1RXD COM1TXD COM1DTRL FRONT_GND FRONT_GND RS485 COM1DCDL COM1RXD FRONT_GND FRONT_GND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 27: Com 3 Port

    Connector location: COM4 Definition Definition Definition Definition COM3DCDL COM3RXD COM4DCDL COM4RXD COM3TXD COM3DTRL COM4TXD COM4DTRL COM3DSRL COM4DSRL COM3RTSL COM3CTSL COM4RTSL COM4CTSL RI_VCC12_VCC5 COM4RIL Front_GND Front_GND Front_GND Front_GND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 28: Usb3.1 Ports

    Connector location: USB1 Connector location: SW1 Definition Definition Definition 5VUSB1 USB2N_5 PM_RESET#_J USB2P_5 S_USB31_RXN5 S_USB31_RXP5 USB31_TXN5 USB31_TXP5 5VUSB1 USB2N_6 USB2P_6 S_USB31_RXN6 S_USB31_RXP6 USB31_TXN6 USB31_TXP6 FRONT_GND FRONT_GND FRONT_GND FRONT_GND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 29: External I/O Interfaces - Rear Panel

    USB31_TXN3 USB31_TXN1 USB31_TXP3 5VUSB4 USB31_TXP1 5VUSB3 USB2N_4 USB2P_4 USB2N_2 USB2P_2 S_USB31_RXN4 S_USB31_RXN2 S_USB31_RXP4 S_USB31_RXP2 USB31_TXN4 USB31_TXP4 USB31_TXN2 USB31_TXP2 REAR_GND REAR_GND REAR_GND REAR_GND REAR_GND REAR_GND REAR_GND REAR_GND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 30: Dc In Connector

    Definition Definition Definition 12VSB 12VSB HDMI1_TX2_P_CN HDMI1_TX2_N_CN HDMI1_TX1_P_CN REAR_GND HDMI1_TX1_N_CN REAR_H_GND REAR_H_GND HDMI1_TX0_P_CN REAR_GND HDMI1_TX0_N_CN HDMI1_CLK_P_CN HDMI1_CLK_N_CN HDMI1_CEC HDMI1_SCL HDMI1_SDA HDMI1_PWR_C HDMI1_HPD_C REAR_GND REAR_GND REAR_GND REAR_GND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 31: Hdmi2 Connector

    HDMI2_TX0_P_CN HDMI3_TX0_P_CN HDMI2_TX0_N_CN HDMI2_CLK_P_CN HDMI3_TX0_N_CN HDMI3_CLK_P_CN HDMI2_CLK_N_CN HDMI3_CLK_N_CN HDMI2_CEC HDMI3_CEC HDMI2_SCL HDMI2_SDA HDMI3_SCL HDMI3_SDA HDMI2_PWR_C HDMI3_PWR_C HDMI2_HPD_C REAR_GND HDMI3_HPD_C REAR_GND REAR_GND REAR_GND REAR_GND REAR_GND REAR_GND REAR_GND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 32: Lan1 I219 Connector

    MDI_PLUS3 MDI_MINUS2 LAN2MDI1P LAN2MDI1N MDI_PLUS2 MDI_MINUS1 LAN2TCT MDI_PLUS1 MDI_MINUS0 LAN2MDI2P LAN2MDI2N MDI_PLUS0 LAN2MDI3P LAN2MDI3N LAN1ACTPW LAN1LEDACTN LAN2ACTCON LAN2LEDACTN LAN1LED100# LAN1LINK LAN2_LINK1000# LAN2_LINK100# REAR_GND REAR_GND REAR_GND REAR_GND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 33: Mic In (Pink) Connector

    Mic In (Pink) Connector Audio Connector Connector location: CN1 Connector location: CN2 Line-Out Mic-In Definition Definition Definition Definition AGND MIC_OUT-L LINE_OUT_RC LINEOUT_JD AGND MIC_JD AGND LINE_OUT_LC MIC_OUT-R AGND Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 34: Internal Connectors

    Connector type: 1x4 4-pin Wafer, 2.54mm pitch Connector location: J2 Connector location: FAN1 Definition Definition Definition Definition SIO_PLTRSTN VCC12 CLKOUT_LPCI ESPI_CS0# FANIN1 FANOUT1 ESPI_IO3 ESPI_IO2 ESPI_IO1 ESPI_IO0 SERIRQ VCC3 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 35: Fan2 Connector

    Connector type: 2x5 10-pin header, 2.0mm pitch Connector location: FAN2 Connector location: GPIO Definition Definition Definition Definition VCC12 GPIO_PWR FANIN2 FANOUT2 GPO0_OUT GPI0_IN GPO1_OUT GP1_IN GPO2_OUT GPI2_IN GPO3_OUT GPI3_IN Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 36: Sata Connector

    Connector type: 1x5 5-pin header, 2.0mm pitch Connector location: SATA1 Connector location: SPEK Definition Definition Definition Definition SATA_TXP2 OUT-LR+_C OUT-LR-_C SATA_TXN2 OUT-RR+_C SATA_RXN2 SATA_RXP2 OUT-RR-_C SATA_5V SATA_5V SATA_5V Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 37: Reset/Put Connector

    Connector type: 1x4 4-pin header, 2.54mm pitch Connector type: 2x6 12-pin header, 2.0mm pitch Connector location: JP2 Connector location: PW1 Definition Definition Definition Definition H_PWRBTN#_M 12VSB PM_RESET#_J 12VSB 12VSB 12VSB 12VSB 12VSB Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 38: Usb2.0 Pin Header Connector

    Connector type: 1x6 6-pin header, 2.0mm pitch (NDiS B560-Q370 Only) Connector location: USB4 Connector location: USB5 Definition Definition Definition Definition P5V_USB_P10 USB2N_10 P5V_USB_P1213 USB2N_12 USB2P_10 USB2N_11 USB2P_12 USB2N_13 USB2P_11 USB2P_13 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 39: Smabus Pin Header

    Connector type: 1x4 4-pin header, 2.0mm pitch Connector type: 1x5 5-pin header Connector location: SMBUS Connector location: RI Definition Definition Definition Definition VCC3 SMB_CLK VCC5 RI_VCC12_VCC5 SMB_DATA VCC12 RI_VCC12_VCC5 COM3RIL Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 40: Battery Connector

    Battery Connector CON1 Connector Connector type: 1x2 2-pin header Connector type: 2x2 4-pin header Connector location: BAT Connector location: CON1 Definition Definition Definition 3V_BAT1 12VSB 12VSB Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 41: Sim Card Connector

    Chapter 2: Jumpers and Connectors SIM Card Connector Connector location: SIM1 Definition Definition UIM_PWR UIM_RESET UIM_CLK UIM_VPP UIM_DATA Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 42: Ngff Key E Connector

    H_PCIERXN8 NGFF_3V3 I_CLKOUTPCIEP7 M2_E_USBP NGFF_3V3 I_CLKOUTPCIEN7 PCIEREQ#_NGFF_R M2_E_USBN CONFIG_0 H_PCIERXP20 SRCCLKREQ7N CONFIG_1 I_WAKEN CONFIG_2 M2E_PCIE_TXP1 M2E_PCIE_TXN1 GND3VSB H_PCIERXP7 RST_M2E H_PCIERXN7 SRCCLKREQ6N I_WAKEN I_CLKOUTPCIEP6 NGFF_3V3 I_CLKOUTPCIEN6 NGFF_3V3 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 43: Ngff Key M Connector

    H_PCIERXN20 PCIETXP17 M2_PLTRSTN1 H_PCIERXP20 SRCCLKREQ3N DSS#_1 I_CLKOUTPCIEN3 I_WAKEN PCIETXN20 3VSB I_CLKOUTPCIEP3 PCIETXP20 3VSB 3VSB H_PCIERXN19 3VSB H_PCIERXP19 PCIETXN19 I_SUSCLK2 PCIETXP19 S_SATAXPCIE4 3VSB 3VSB H_PCIERXN18 3VSB H_PCIERXP18 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 44: Ngff Key B Connector

    H_USB31_TXN7 UIM_PWR H_USB31_TXP7 Definition Definition CONFIG_3 3VSB 3VSB POWEROFF M2_B_PERST S_USB2P_2 M2LTEDISL S_USB2N_2 M2_B_PEWAKE CONFIG_0 I_WAKEN M2LTERSTL M2LTECONFIG1 3VSB 3VSB H_USB31_RXN7 UIM_RESET 3VSB H_USB31_RXP7 UIM_CLK M2LTECONFIG2 Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 45: Block Diagram

    (Rear) (Rear) GPIO 4 in/4 out USB2 PORT10-13 USB2 x2 USB2 PORT10-13 Q370=OK H310=NA USB2 x2 4 Pin DC Jack 4 Pin ATX conn (+12V) (+12V) Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 46: Chapter 3: System Setup

    1. The screws on the front, rear and bottom are used to secure the cover to the chassis. Remove these screws and put them in a safe place for later use. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 47 Chapter 3: System Setup 2. Remove the top cover. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 48: Installing A Cpu

    1. Remove the four screws and CPU heatsink. CPU Socket Retention Tab Load Lever 3. Lift the load lever up to open the CPU retention bracket. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 49 ▪ The CPU will fit only in one CAUTION! CAUTION! CAUTION! socket may bend the pins and damage the CPU. orientation and can easily be inserted without exerting any force. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 50 Chapter 3: System Setup 6. Align the CPU heatsink. 7. Secure the CPU heatsink with the four screws. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 51: Installing A So-Dimm (Dimm2)

    The ejector tabs at the ends of the socket will automatically snap into the locked position to hold the module in place. 1. Locate the SO-DIMM socket on the board. Memory module SO-DIMM socket Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 52: Installing A So-Dimm (Dimm1)

    1. Remove the screw from the SO-DIMM cover at the bottom side. 3. Secure the SO-DIMM cover with the screw. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 53: Installing A Hdd

    Please correctly follow the below instructions and CAUTION! CAUTION! CAUTION! noted items to avoid making unnecessary damages. 1. Secure the HDD bracket to the HDD with the four screws. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 54 3. Insert the HDD and the SATA connector and then secure the HDD with the HDD bracket to the board with the four screws. SATA connector Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 55: Installing A M.2 Storage Module

    3. Insert the M.2 module into the M.2 slot at a 45-degree angle until the gold-plated connector on the edge of the module completely dissapears into the slot. M.2 M-key slot Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 56 5. When purchasing a M.2 storage, it is recommended to use a (From step 2) complementary dedicated thermal pad. Stick it to the original set of M.2 module for a better heat dissipation. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 57: Installing A M.2 Wifi Module

    (E-key 2230) 2. Remove the screws, and keep it for later use. (For step 4) 1. Locate the M.2 M-key slot on the board. M.2 E-key slot Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 58 4. Push the WiFi module down and secure it with the screw. (From step 2) until the gold-plated connector on the edge of the module completely dissapears into the slot. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 59: Assembling The Top Cover To The Chassis

    Chapter 3: System Setup Assembling The Top Cover To The Chassis 1. Align the top cover and PCB. Heatsink for memory module Memory module Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 60 Chapter 3: System Setup 2. Slide the top cover to the chassis and secure it with the 10 screws. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 61: Installing A M.2 Lte/5G Module

    (B-key 3042/3052) and SIM card 1. Remove the screw from the LTE cover at the bottom side. 2. Remove the screws, and keep it for later use. (For Step 4) Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 62 30 degrees angle. The ejector tabs at the ends of the socket will (From step 2) automatically snap into the locked position holding the module in place. LTE/5G module M.2 B-key slot Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 63 5. Open the SIM card holder and place the SIM card onto the holder. 6. Close the holder and secure it to the original position. SIM card holder SIM card 7. Secure the LTE cover with the screw. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 64: Chapter 4: Bios Setup

    BIOS is updated in the future. second, to make settings appropriate for the way you use the computer. To check for the latest updates and revisions, visit the NEXCOM Web site at When to Configure the BIOS www.nexcom.com.tw.
  • Page 65: Default Configuration

    Powering on the computer and immediately pressing <Del> allows you to enter Setup. Load optimized default values. Press the key to enter Setup: Saves and exits the Setup program. Press <Enter> to enter the highlighted sub¬menu Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 66 When “” appears on the left of a particular field, it indicates that a submenu which contains additional options are available for that field. To display the submenu, move the highlight to that field and press Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 67: Bios Setup Utility

    00 to 23. Minute displays minutes from 00 to 59. Second displays Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. seconds from 00 to 59. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 68: Advanced

    Select the number of cores to enable in each processor package. Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. Hyper-Threading This field is used to enable or disable hyper-threading. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 69 Configures the CPU power management control options. Enables or disables Intel SpeedStep. Turbo Mode Enables or disables turbo mode. C states Enables or disables CPU C states support for power saving. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 70 Enable or disable Intel (R) Manageability features. This option disables/ enables Manageability Features support in FW. To disable, support platform must be in an unprovisioned state first. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 71 Activate Remote Assistance Process Enables or disables Alert Standard Format support. Enables or disables Activate Remote Assistance Process. USB Provisioning of AMT Enables or disables USB Provisioning of AMT. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 72 Enables or disables the option to add ASF Sensor Table into ASF ACPI Table. Enables or diables the option to Force Secure Erase on next boot. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 73 MEBx Selection Screen Enables or disables MEBx selection screen with 2 options. • Press 1 to enter ME configuration screens. • Press 2 to initiate a remote connection. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 74 SHA-1 PCR Bank Enables or disables SHA-1 PCR Bank. Graphics Mode Resolution Configures the resolution for graphics mode. SHA256 PCR Bank Enables or disables SHA256 PCR Bank. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 75 TPM 2.0 devices if not found, and TPM 1.2 devices will be enumerated. Disable Block Sid Enables or disables the option to allow SID authentication in TCG storage device. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 76 Enables or disables the serial port. Onboard Serial Port Mode Select this to change the serial port mode to RS232, RS422, RS485 No Terminator or RS485 With Terminator. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 77 Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. Serial Port Serial Port Enables or disables the serial port. Enables or disables the serial port. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 78 Detects and displays the current fan speed of the fans connected to Fan 1 USB transfer time-out and Fan 2. The time-out value for control, bulk, and Interrupt transfers. VCORE to +3.3V Detects and displays the output voltages Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 79 +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 80 Configures the items used for self test. Controller Only Test and Controller and NameSpace Test options are available. Selecting Controller and NameSpace Test will take longer to complete. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 81 Ipv4 PXE Support Enables or disables IPv4 PXE support. If disabled, the IPv4 boot option will not be created. Ipv4 HTTP Support Enables or disables IPv4 HTTP support. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 82 F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. NIC Configuration Enters the network configuration sub-menu of the network controller. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 83: Chipset

    Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. PEG Port Configuration Enters the PEG Port Configuration submenu. Setting incorrect field values may cause the system to malfunction. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 84 Enables or disables the root port. Internal Graphics Max Link Speed Keep IGD enabled based on the setup options. Configures the maximum link speed of the PEG device. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 85: Pch-Io Configuration

    Enables or disables integrated LAN to wake the system. State After G3 Configures the power state when power is re-applied after a power failure (G3 state). Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 86: Hd Audio Configuration

    Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. HD Audio Control detection of the HD audio device. Disabled HD audio will be unconditionally disabled. Enabled HD audio will be unconditionally enabled. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 87: Edid Mode Control

    Administrator Password Configures the EDID resolution for EDID1 to EDID3. Select this to reconfigure the administrator’s password. User Password Select this to reconfigure the user’s password. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 88: Boot

    NumLock on wherein the function of the numeric keypad is the number keys. When set to Off, the function of the numeric keypad is the arrow keys. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...
  • Page 89: Save & Exit

    To bypass the boot sequence from the Boot Option List and boot from a Version 2.20.1275. Copyright (C) 2021 American Megatrends, Inc. particular device, select the desired device and press <Enter>. Copyright © 2024 NEXCOM International Co., Ltd. All Rights Reserved. NDiS B560-Q User Manual...