EMC Guidance and Manufacturer's Declaration
Guidance and manufacturer's declaration – electromagnet emissions.
The M-910 is intended for use in the electromagnetic environment specified below. The customer or user of this scale should
ensure that it is used in such environment.
Emission Test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/flicker emissions
IEC 61000-3-3
Guidance and manufacturer's declaration – electromagnetic immunity.
The M-910 is intended for use in the electromagnetic environment specified below. The customer or the user of this scale
should ensure that it is used in such an environment.
Immunity Test
IEC 60601 Test Level
Electrostatic
discharge (ESD)
IEC 61000-4-2
Electrical fast
transient/burst
lines +1 kV for input/output
IEC 61000-4-4
lines
Surge IEC 61000-4-
5
kV line(s) to earth
Voltage Dips, short
<5% UT (>95% dip in UT) for
interruptions and
0.5 cycle 40% UT (60% dip
voltage variations on
in UT) for 5 cycles 70% UT
power supply input
(30% dip in UT) for 25 cycles
lines IEC 61000-4-11
<5% UT (>95% dip in UT) for
5s
Power frequency
3 A/m
(50/60 Hz) magnetic
field IEC 61000-4-8
Guidance and manufacturer's declaration – electromagnetic immunity.
This scale is intended for use in the electromagnetic environment specified below. The customer or the user of the scale should
ensure that it is used in such an environment.
Immunity Test
IEC 60601 test level
Conducted RF
3 Vrms
IEC 61000-4-6
150 KHx to 80 MHz
Compliance
Group 1
Class B
Class A
Compliance
6 kV contact
8 kV air
2 kV for power supply
1kV line(s) to line(s)
2
Note UT is the A.C mains voltage prior to application of the test level.
Compliance Level
6 kV contact
8 kV air
2 kV for power supply
lines not applicable
1 kV differential mode
not applicable
<5% UT (95% dip in UT)
for 0.5 cycle 40% UT
(60% dip in UT) for 5
cycles 70% UT (30% dip
in UT) for 25 cycles <5%
UT (>95% dip in UT) for
5s
3 A/m
Compliance level
3 Vrms
Electromagnetic environment-
guidance
This scale uses RF energy only for its
internal function. Therefore, its RF
emissions are very low and not likely to
cause any interference in nearby
electronic equipment.
This scale is suitable for use in all
establishments, including domestic
establishments and those directly
connected to the public low-voltage
power supply network that supplies
buildings used for domestic purposes.
Electromagnetic Environment
Guidance
Floors should be wood, cement or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30%.
Mains power quality should be that of a
typical commercial or hospital
environment.
Mains power quality should be that of a
typical commercial or hospital
environment.
Mains power quality should be that of a
typical commercial or hospital
environment. If the user of this scale
requires continued operation during
power mains interruptions, it is
recommended that this scale is
powered from an uninterruptable
power supply or a battery.
The scale's power frequency magnetic
fields should be at levels characteristic
of a typical location in a typical
commercial or hospital environment.
Electromagnetic environment-
guidance
Portable and mobile RF
communications equipment should be
used no closer to any part of the scale
including cables, than the
recommended separation distance
calculated from the equation
applicable to the frequency of the
transmitter.
Page 13 of 16