12/13
Field settings table
Breadcrumb Field code
Setting name
9.I
[D-03]
Leaving water temperature compensation around 0°C.
9.I
[D-04]
Is a demand PCB connected?
9.I
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
9.I
[D-07]
Is a solar kit connected?
9.I
[D-08]
Is an external kWh meter used for power measurement?
9.I
[D-09]
Is an external kWh meter used for power measurement, kWh meter used for smart
grid or a gas meter for hybrid unit?
9.I
[D-0A]
--
9.I
[D-0B]
--
9.I
[D-0C]
--
9.I
[D-0D]
--
9.I
[D-0E]
--
9.I
[E-00]
Which type of unit is installed?
9.I
[E-01]
Which type of compressor is installed?
9.I
[E-02]
What is the indoor unit software type?
9.I
[E-03]
What is the number of backup heater steps?
9.I
[E-04]
Is the power saving function available on the outdoor unit?
9.I
[E-05]
Can the system prepare domestic hot water?
9.I
[E-06]
--
9.I
[E-07]
What kind of DHW tank is installed?
9.I
[E-08]
Power saving function for outdoor unit.
9.I
[E-09]
--
9.I
[E-0B]
Is a bizone kit installed?
9.I
[E-0C]
What bizone system type is installed?
9.I
[E-0D]
Is the system filled with glycol ?
9.I
[E-0E]
--
9.I
[F-00]
Pump operation allowed outside range.
9.I
[F-01]
Above which outdoor temperature is cooling allowed?
9.I
[F-02]
--
9.I
[F-03]
--
9.I
[F-04]
--
9.I
[F-05]
--
9.I
[F-09]
Pump operation during flow abnormality.
9.I
[F-0A]
--
9.I
[F-0B]
Close shut-off valve during thermo OFF?
9.I
[F-0C]
Close shut-off valve during cooling?
9.I
[F-0D]
What is the pump operation mode?
Bizone kit settings
9.P.1
[E-0B]
Bizone kit installed
9.P.2
[E-0C]
Bizone system type
9.P.3
[7-0A]
Add zone pump fixed PWM
4P644734-1B - 2022.09
Range, step
Default value
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
R/W
0: No
1: Pwr consmp ctrl
R/W
0: Forced off
1: As normal
R/W
0: No
1: Yes
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
0
2
0
0
0
R/O
0~5
0: LT split
R/O
1
R/W (*5)
0: Reversible (*5)
R/O (*6)
1: Heating only (*6)
R/O
3: 6V (*1)
4: 9W (*2)
R/O
0: No
1: Yes
R/W
0: No (*3)
1: Yes (*4)
1
R/W
0~8
0: EKHW, small volume (*3)
1: Integrated (*4)
3: EKHW, large volume
5: EKHWP (*3)
7: Third party tank, small coil
8: Third party tank, large coil
R/W
0: Disabled
1: Enabled
1
R/W
0: Not installed
1: -
2: Bizone kit installed
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
R/W
0: No
1: Yes
0
R/W
0: Disabled
1: Enabled
R/W
10~35°C, step: 1°C
20°C
3
5
0
0
R/W
0: Disabled
1: Enabled
0
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: Continuous
1: Sample
2: Request
R/W
0: Not installed
1: -
2: Bizone kit installed
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
R/W
20~95%, step: 5%
95%
Installer setting at variance with
default value
Date
Value
(*1) *6V*_(*2) *9W*_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*_(*7) *SU*_
(*8) E_(*9) E7