Daikin ETVH16UE6V7 Installer's Reference Manual page 296

Table of Contents

Advertisement

4/13
Field settings table
Breadcrumb Field code
Setting name
4.A
[D-03]
Increase around 0°C
4.B
[9-04]
Overshoot
4.C
[2-06]
Antifrost
Tank
5.2
[6-0A]
Comfort setpoint
5.3
[6-0B]
Eco setpoint
5.4
[6-0C]
Reheat setpoint
5.6
[6-0D]
Heat up mode
└─ Disinfection
5.7.1
[2-01]
Activation
5.7.2
[2-00]
Operation day
5.7.3
[2-02]
Start time
5.7.4
[2-03]
Tank setpoint
5.7.5
[2-04]
Duration
Tank
5.8
[6-0E]
Maximum
5.9
[6-00]
Hysteresis
5.A
[6-08]
Reheat hysteresis
5.B
Setpoint mode
└─ WD curve
5.C
[0-0B]
Leaving water value for high ambient temp. for DHW WD curve.
5.C
[0-0C]
Leaving water value for low ambient temp. for DHW WD curve.
5.C
[0-0D]
High ambient temp. for DHW WD curve.
5.C
[0-0E]
Low ambient temp. for DHW WD curve.
Tank
5.D
[6-01]
Margin
5.E
WD curve type
User settings
└─ Quiet
7.4.1
Activation
7.4.3
Level
└─ Electricity price
7.5.1
High
7.5.2
Medium
7.5.3
Low
User settings
7.6
Gas price
Installer settings
└─ Configuration wizard
└─ System
9.1.3.2
[E-03]
BUH type
4P644734-1B - 2022.09
Range, step
Default value
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
R/W
1~4°C, step: 1°C
1°C
R/W
0: Disabled
1: Enabled
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
0: No
1: Yes
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0~23 hour, step: 1 hour
1
R/W
[E-07]≠
1:
55~75°C, step: 5°C
70°C
[E-07]=1:
60°C
60°C
R/W
[E-07]≠1:
5~60 min, step: 5 min
10 min
[E-07]=1:
40~60 min, step: 5 min
40 min
R/W
(*3) [E-07]=0 or 7:
40~ 60°C, step: 1°C
60°C
(*3) [E-07]=3 or 5 or 8:
40~80°C, step: 1°C
80°C
(*4) : 40~65°C, step: 1°C
65°C
R/W
2~40°C, step: 1°C
8°C
R/W
2~20°C, step: 1°C
10°C
R/W
0: Fixed
1: Weather dependent
R/W
35~[6-0E]°C, step: 1°C
55°C
R/W
45~[6-0E]°C, step: 1°C (*8)
Min(45,[6-0E])~[6-0E]°C, step: 1°C (*9)
60°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
0~10°C, step: 1°C
2°C
R/O
0: 2-points
1: Slope-Offset
R/W
0: OFF
1: Manual
2: Automatic
R/W
0: Quiet
1: More Quiet
2: Most Quiet
R/W
0,00~990/kWh
1/kWh
R/W
0,00~990/kWh
1/kWh
R/W
0,00~990/kWh
1/kWh
R/W
0,00~990/kWh
0,00~290/MBtu
1,0/kWh
R/O
3: 6V (*1)
4: 9W (*2)
Installer setting at variance with
default value
Date
Value
(*1) *6V*_(*2) *9W*_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*_(*7) *SU*_
(*8) E_(*9) E7

Advertisement