Transport And Storage - Boyser RBT Series Operating Instructions Manual

Peristaltic pump
Table of Contents

Advertisement

Operating instruccions Peristaltic Pumps
7.

TRANSPORT AND STORAGE

7.1.
Transport
- The pump is protected by cardboard packaging or a wooden crate.
- The packaging materials are recyclable.
7.2.
Storage for less than 1 month
- The pump should be in a resting position, rotor in horizontal position.
- Avoid areas open to harsh weather or excessive humidity and temperatures lower
than 0°C or higher than 30°C.
- Spare hoses should be stored in a dry place away from direct light.
7.3.
Storage for more than 1 month
- Avoid areas open to harsh weather or excessive humidity and temperatures lower
than 0°C or higher than 30°C.
- IMPORTANT Disassemble one of the shoes (see also section 9.4.1 for instructions):
- Remove the front cover.
- Remove a shoe (the shoe that is not touching the pump hose).
- Mount the front cover.
- Turn the rotor with the help of the motor so that the remaining shoe
- For storage periods of longer than 30 days, protect the coupling surfaces (clamps,
reducers, motors) with adequate anti-rust protection.
- For storage periods longer than 6 months rotate the rotor a few turns to prevent
damage to bearings and oil seals and to prevent grease migration.
- Spare hoses should be stored in a dry place away from direct light.
7.4.
Elevation
Models RBT- 25, RBT-32, RBT-40
Weights
Total pump
weight
Max. rating of
the lifting point
Safety factor
RBT Series
is not pressing against the pump hose.
RBT-25
96 kg
211 lbs
170 kg
374 lbs
6
RBT-32
145 kg
319 lbs
170 kg
374 lbs
6
10
RBT-40
196 kg
432 lbs
240 kg
529 lbs
6