B. PRIMARY/TRANSFER
CORONA
ASSEMBLY
1. Outline
The primary and transfer corona assem-
blies are located around the photosensitive
drum. The primary corona assembly has a
grid.
2. Disassembly/Reassembly
a. Removing the primary corona assembly
grid plate.
1) Remove the drum CARTRIDGE.
Note:
The photosensitive
drum is adversely
af-
fected
by strong light, so blank areas or
black
bands
may occur
if the drum
is
exposed to strong light
for
a long period. Do
not, therefore,
expose the drum to light.
2) Unscrew the two screws, then remove
the primary corona assembly from the
photosensitive
drum.
OS crews
@ Primary corona
unit
Figure 4-46
b. Removing the guide wire/static
charge
eliminator
of the
transfer
corona
assembly.
1) Remove the transfer corona assembly
from the copier.
2) Unscrew the two screws, then pull the
static charge eliminator
to separate it
from the guide wire.
@ Mounting screws
Figure 4-47
3) Remove the static charge eliminator.
@ Static charge eliminator
Figure 4-48
C. Attaching
the
corona
wires
of the
primary/transfer
corona assembly.
1) Primary corona unit, remove the four
tension springs then remove the grid
plate, as shown in the figure.
@ Grid wire tension
@ Grid plate
Figure 4-49
COPYAIGHT
0
1900 CANON INC.
CANON NP-101511215S
AN.0
OCT. 1980 PAINTEO
IN JAPAN IIMPAIMf
AU JAPONI
4 - 15