115VAC @ 60Hz or 230VAC @ 50Hz
operation
•
AC input fused at 1 Amp @ 115VAC or 0.5
Amp @ 230VAC
•
Override page on separate tip/ring
temporarily disconnects page in progress
and issues an override busy tone to
overridden party
•
Normal paging is restored after override
•
Inhibit circuitry (Speaker cancel)
•
UL Listed
Additional Features Supplied by the
V-2003AHF
•
3 zones of handsfree talkback, one-way or
mixed paging
•
Dip switch programmable per zone (Music,
tones and one-way or talkback)
•
Pre-announce tone (Optional)
•
Repeated alert tone (Optional)
•
Two volume controls for handsfree paging
- Page (Phone to speaker)
- Receive (Speaker to phone)
•
Supplies 10 Valcom power units (-24VDC,
0.5 Amp) for powering one-way amplified
speakers (A reduction of 10 power units
from the V-2003A)
Priority Sequence
The V-2003A and V-2003AHF Units are
designed with the following priority (1 = highest;
5 = lowest):
___1.
Time clock signal
___2.
Override page
___3.
System page
___4.
Night right
___5.
Music
Physical Description
The V-2003A and V-2003AHF are contained in
single, gray steel cases, which can be wall or
shelf-mounted.
V-2003A
Dimensions:
7.10"H x 10.00"W x 3.00"D
(18.03cm x 25.40cm x 7.62cm)
Weight:
V-2003AHF
Dimensions:
7.10"H x 10.00"W x 3.00"D
(18.03cm x 25.40cm x 7.62cm)
Weight:
Nominal Specifications
Input Impedance:
Input Level:
Music Source Impedance:
4.1 lbs. (1.86 kg)
5.6 lbs. (2.54 kg)
600 Ohms
-10dBm
8 to 600 Ohms
2
Music Input Level:
Output Impedance:
Output level:
DC Output:
-24VDC at 1 Amp (V-2003A)
-24VDC at 0.5 Amp (V-2003AHF)
Nominal Power Requirements
Voltage:
115VAC
230VAC
Battery Backup
The V-2003A/V-2003AHF is equipped with a
standard 3-prong MOLEX connector to allow
connection of a fused output battery backup
supply (3 Amp, Valcom VPB-260 or equivalent)
in case of AC power failure. Backup time will be
a function of system usage.
•
Use a cord set consisting of a minimum 18
AWG cord and grounding type attachment
plug rated a minimum of 15A, 250V. The
cord set should have the appropriate safety
approvals for the country in which the
equipment will be installed and marked
HAR.
•
The socket outlet shall be installed near the
equipment and shall be easily accessible.
Environment
Temperature:
Humidity:
0 to 85% non-condensing
OPERATION
General
Press the line key (Electronic Key System), dial
the trunk access code (PABX) or dial the page
port access code to access the
V-2003A/V-2003AHF; with dedicated single line
sets - simple go off hook. The
V-2003A/V-2003AHF will return dial tone (If so
optioned). Dial desired zone code: 1, 2, 3, or 5,
6, 7 for individual zones (1 through 3
respectively). Dial 4 or 8 for the all call of all
zones. Ringback tone (If so optioned) will be
heard in the telephone receiver. Make
announcement and hang up. The unit will
automatically disconnect from page. Ringback
tone and repeated alert tones, when optioned,
provide an alert tone to the talkback zones on a
V-2003AHF. The repeated alert tones will
broadcast every 15 seconds when the zone is
active in the handsfree mode.
-10 to -18dBm
8 Ohms (1 way)
45 Ohms (Talkback)
-10dBm (1 way)
1 Watt (Talkback)
Current:
1 Amp
0.5 Amp
0 to +40 Degrees C
Need help?
Do you have a question about the V-2003A and is the answer not in the manual?
Questions and answers
when connecting to a Valcom 2003a will a station port work? or do you need to use a trunk, or page port for paging access
A station port can work for paging access on a Valcom V-2003A, but it requires a Valcom V-9970 to be installed between the IP Office and the V-2003A. Normally, the V-2003A is intended for use with a loop start trunk port.
This answer is automatically generated