6. COMMUNICATIONS IN THE BIDIRECTIONAL MODE
MELSEC-A
6.1
Setting Switches on the Computer Link Module AJ71UC24
Set the setting switches on the AJ71 UC24 as shown below:
Station number,
setting switches
x 1
@
e t
S e t
the switches to
station number
0.
J
\
/I
Mode setting switch
I
(RS-232C
interface: Bidirectional mode)
'
Transmission specifications setting switches
RS-232C
s w 1 4
Transmission speed setting
OFF
(4800BPS)
ON
sw22
Write during RUN
enabiedMlsaMed
'
OFF (DIsaMed)
sw23
Computer IlnUMuitidrop link ON
SW24
Unused
-
selection
(Computer link)
POINT
I
I
When a module other than the AJ71UC24 is used
as computer link
module, data communications described hereinafter can be executed
by setting the corresponding switches as shown above.