Maintenance

Warning! Isolate from the electrical supply
before performing any work on the unit.
The internal air filter is removable for servicing.
To gain access to the filter unlock and lower the
front access panel, remove the 2 screws from the
filter enclosure panel and lift out. Carefully lift
out and remove filter. The filter should be gently
tapped to remove any accumulated dust and
vacuumed if necessary (approx. every 6 months).
We recommend replacing the filters approx. every
2 years depending on environmental conditions.

Fault finding

Providing the power supply is switched on the room thermostat (if fitted) is calling for heat the heater will
switch on and off automatically with the central heating system.
In the event of any difficulty, please contact us on +44 (0) 1245 324560.
It will be helpful if you do not disconnect the heater from the central heating system.
Fault
The fan does not run on any speed setting
No heat output
20 | SmithsEP.co.uk | Issue 001 - October 2023
The coil fins are delicate so take care and only use
a soft brush or vacuum cleaner to remove any
dust that may have accumulated.
Checking/Solution
Check the power supply is switched ON
Check the fuse in the fused spur
Check the wiring at the fused spur
If thermostat is fitted ensure it is calling for heat
Check the central heating is switched ON
Vent any trapped air from the system (with the heating system turned OFF)
Check flow and return pipes are hot
Vent any trapped air from the system (with the heating system turned OFF)
Check the central heating is switched ON
If a thermostat is fitted ensure it is calling for heat
Balance the central heating system if installed on the same circuit as panel
radiators and increase the circulating pump speed if required
Increase the boiler water temperature