Table Of Contents; Introduction - Swann Smith's Caspian UVC EC Series Installation, Commissioning And User Manual

Variants with smart controls
Table of Contents

Advertisement

Contents
your thermostat
2 | SmithsEP.co.uk | Issue 001 - October 2023

Introduction

2
Suitable for Caspian (UVC)
3
These heaters must not be installed in wet rooms
3
or other high humidity areas.
4
These heaters are designed for use on standard
5
two-pipe pumped central heating systems with
a maximum water temperature of 86°C and a
6
maximum pressure of 6 bar (88lbs/in.).
7
Pipe connections are 22mm, in order to obtain
9
maximum efficiency and output the flow should
10
be connected to the header tube which is nearest
12
the exiting air side of the heat exchanger.
13
When mounting the zone valve to the system
14
pipework the arrows indicating flow direction
must be observed and respected.
15
15
These heaters are classified as a fixed appliance
and the electrical connection should be via a 3A
fused spur. The fused spur must not be directly
16
below the heater but should be accessible after
20
completion of the installation. All heaters must be
20
earthed.
21
To avoid the possibility of vibration these units
21
must be fitted to a flat even surface.
22
This heater is fitted with a 35°C Low Temperature
23
Cut-out (LTC). An adjustable low temperature
cut-out is also available (see page 10).
23
23
To conform to Building Regulations Part L (Part J
in Scotland), a remote room thermostat can be
used in conjunction with this heater. Refer to the
instructions supplied with the thermostat.
Please note the guarantee may be invalidated
if this product is not installed and used in
accordance with these instructions.