Low battery voltage
When the battery is discharged to less than the Low Voltage
Disconnect (LVD) voltage, the controller will disable the load
output. After over-discharge the load output will be re-enabled
when the battery voltage reaches the Low Voltage Reconnect
(LVR) level.

Over-current protection.

A load output over-current or short-circuit is indicated by a
flashing load icon. The controller will disable the load output and
try to re-enable after 30 seconds.
Shut down after 60s in case of 110%-130% load.
Shut down after 5s in case of 130%-160% load.
Short-circuit protection
In case of a short-circuit the controller will switch off the load
output and wait for 30s and then try to restart.
USB voltage high.
Disconnect the USB load. If the alarm persists the USB output is
defect.
Wiring error or short circuit in the charge controller
Wiring error: the minus of the solar panel is connected
to the minus of the battery.
Internal defect.
Open circuit in the charge controller
Internal defect.
Open circuit in the load output circuit
Internal defect.