ACDC Header
Feature
Rated Charge Current
Battery Voltage
Auto Load Disconnect
Max Solar Voltage
Self Consumption
Load OutputManual control + Low voltage disconnect
Protection
Battery reverse polarity (fuse)
Output Short circuit
Over Temp
Overload Protection
Shut down after 60sec with load at 130%
Shut down after 5sec with load 160%
Short circuit immediate shutdown
Grounding
Common Positive
‐20 to 50⁰C
Operating Temperature
Humidity
Max 95%RH
Battery
Charge Voltage "Absorption" 14.2 / 28.4V
Charge Voltage "Float"
13.8 / 27.6V
Low Voltage Load Disconnect
11.2 / 22.4V
Low Voltage Load Reconnect
12.6 / 25.2V (manual)
13.1 / 26.2V (automatic)
Enclosure
Protection Class
Terminal Size
Weight
Dimensions (HxWxD)mm 70 x 133 x 33.5
Bluesolar-5, Bluesolar-10
Features
Load output with low battery voltage disconnect function.
Lighting control function, one timer only.
Two digit display for parameter setting.
Three stage charging (Bulk, Absorption, Float)
Over load and short circuit protected.
Reverse polarity protected.
Day / Night timing functions.
Bluesolar-5
Bluesolar-10
5A
12/24V with auto system voltage detection
Yes
28V / 55V(1)
10mA
IP20
5mm²
0.15kg
10A
Need help?
Do you have a question about the Bluesolar-5 and is the answer not in the manual?
Questions and answers