8. Mechanical Operating Conditions

8-1. Stroke range
Use a mechanical operating product within the stroke range calculated by the formula below.
Stroke range = (P.T. + 0.5 x O.T.) to (P.T. + O.T. -0.1)
Actuator
Basic
Roller lever
One way lever
8-2. Maximum angle and maximum speed limit for cam and dog
Actuator
Roller lever
One way roller lever
8-3. Cam and dog materials
Roller material
Polyacetal
T.T.=4.8mm
(T.T=2.5mm)
Max. angle for dog
Dog material
Metal
Stroke range (mm)
3.7 ~ 4.7
(2.2~2.4)
3.5 ~ 4.4
3.5 ~ 4.4
30
o
o
45
o
30
o
45
Finish accuracy for dog
13
Max. speed for dog (m/s)
(m/s)
0.7
0.3
0.7
0.3
Rz 6.3 or less