Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Page 4
Safety Instructions Caution We develop, design, and manufacture our products to be used for automatic control equipment, and provide them for peaceful use in manufacturing business. Use in non-manufacturing business is not covered. Products we manufacture and sell cannot be used for the purpose of transactions or certification specified in the Measurement Act.
Page 5
Design precautions / Selection Warning ! 1. Confirm the specifications. The product is designed for use only in compressed air systems. Do not use fluids other than compressed air. Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction.
Page 6
Piping Caution ! 1. Before piping Before piping, perform air blow (flushing) or cleaning to remove any cutting chips, cutting oil, dust, etc. from the piping. 2. Sealant tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not enter the Shuttle valve piping.
Page 7
Air Supply Warning ! 1. Use clean air. Do not use compressed air that contains chemicals, organic solvents based synthetic oils, salts or corrosive gases, etc., as this can cause damage or malfunction. Caution ! 1. Install air filters. Install air filters close to valves on the upstream side. A filtration degree of 5 micrometer or less should be selected.
Caution ! 1. Avoid using in a location where it could be splashed by liquids such as oils, coolant and water, and dust. Maintenance Warning ! 1. Removal of equipment, and supply/exhaust of compressed air When equipment is serviced, first confirm that measures are in place to prevent dropping of driven objects and/-or equipment running out of control, etc.
4.Working Principle When air is supplied to either IN port, it is output from the OUT port. If the supply pressures are different from each other, the higher pressure is output to the OUT side. This product can also be used when the pressures are the same. When no pressure is applied to both IN ports, reverse flow from the OUT port can also be performed.