Download Print this page

SMC Networks VR1210 Series Operation Manual

Shuttle valve

Advertisement

Quick Links

Document No. DOC1062055
Pr oduct Name
Shuttle Valve
Model/ Series
VR1210/1220 Series

Advertisement

loading

Summary of Contents for SMC Networks VR1210 Series

  • Page 1 Document No. DOC1062055 Pr oduct Name Shuttle Valve Model/ Series VR1210/1220 Series...
  • Page 2: Table Of Contents

    Contents 1. Safety Instructions 2. Application 3. Specifications 4. Working Principle 5. Construction...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 4 Safety Instructions Caution We develop, design, and manufacture our products to be used for automatic control equipment, and provide them for peaceful use in manufacturing business. Use in non-manufacturing business is not covered. Products we manufacture and sell cannot be used for the purpose of transactions or certification specified in the Measurement Act.
  • Page 5 Design precautions / Selection Warning ! 1. Confirm the specifications. The product is designed for use only in compressed air systems. Do not use fluids other than compressed air. Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction.
  • Page 6 Piping Caution ! 1. Before piping Before piping, perform air blow (flushing) or cleaning to remove any cutting chips, cutting oil, dust, etc. from the piping. 2. Sealant tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not enter the Shuttle valve piping.
  • Page 7 Air Supply Warning ! 1. Use clean air. Do not use compressed air that contains chemicals, organic solvents based synthetic oils, salts or corrosive gases, etc., as this can cause damage or malfunction. Caution ! 1. Install air filters. Install air filters close to valves on the upstream side. A filtration degree of 5 micrometer or less should be selected.
  • Page 8: Application

    Caution ! 1. Avoid using in a location where it could be splashed by liquids such as oils, coolant and water, and dust. Maintenance Warning ! 1. Removal of equipment, and supply/exhaust of compressed air When equipment is serviced, first confirm that measures are in place to prevent dropping of driven objects and/-or equipment running out of control, etc.
  • Page 9: Working Principle

    4.Working Principle When air is supplied to either IN port, it is output from the OUT port. If the supply pressures are different from each other, the higher pressure is output to the OUT side. This product can also be used when the pressures are the same. When no pressure is applied to both IN ports, reverse flow from the OUT port can also be performed.
  • Page 10 Revision history Renewal. 2023.12 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. ©...

This manual is also suitable for:

Vr1220 seriesVr1210-f01Vr1210-n01Vr1220-f02Vr1220-n02