3. Removal of Damper Motor

Procedure
Step
1. Removal of the damper
motor
Disconnect the
1
connector for the
damper motor.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Humidifying thermistor
Removal of Damper Motor
Disconnect the connector
for the humidifying rotor
motor. (Refer to page 8.)
Harness ASSY
Damper
motor
(R10348)
(R0232)
Points
9