Electrical Specifications; Leveling Information; Installation Tip - U-Line Echelon CO2175FF Installation Manual

Echelon series ice maker/refrigerator
Hide thumbs Also See for Echelon CO2175FF:
Table of Contents

Advertisement

7 Prepare Power Supply

Electrical Specifications

CAUTION
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.
See Figure 35 for recommended receptacle location.
1-1/2"
Figure 35
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
• Never use an extension cord to connect power to
the unit.
Go on to 8 Level the Unit.
www.U-LineService.com
CO2175FF — Combo® Ice Maker/Refrigerator
24"
7"
8 Level the Unit

Leveling Information

It is extremely important that the unit is level. If it is not
level, the ice mold will not fill evenly.
1. Use a level to check
the levelness of the
ice maker from front
to back and from side
to side. Level should
be placed along top
edge and side edge
as shown (see Figure
36).
2. If the ice maker is not level, adjust the feet on the
corners of the unit as necessary (see Figure 37).
Figure 37
3. Check the levelness after each adjustment and repeat
the previous steps until the unit is level. Go on to
9 Install the Unit.

Installation Tip

If the room floor is higher than the floor in the cut-out
opening, adjust the rear feet to achieve a total unit rear
height of 1/8" less than the opening's rear height. Shorten
the unit height in the front by adjusting the front feet.
This allows the unit to be gently tipped into the opening.
Readjust the front feet to level the unit after it is correctly
positioned in the opening.
14
IMPORTANT
1
Figure 36
Turn Foot to Adjust
ULIN_0193_A
08/2006

Advertisement

Table of Contents
loading

Table of Contents