6 Prepare Power Supply

Electrical Specifications

CAUTION
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.
See Figure 16 for recommended receptacle location.
Figure 16
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
• Never use an extension cord to connect power to
the unit.
Go on to 7 Level the Unit.
www.U-LineService.com
29R Refrigerator
23"
Minimum
7"
1-1/2"
7 Level the Unit

Leveling Information

Note: It is recommended that the unit is level.
Use a level to check the
levelness of the unit from
front to back and from side
to side. Level should be
placed along top edge and
side edge as shown (see
Figure 17). Go on to
8 Install the Unit.
8
Figure 17
02/2005