8.2.4 Specifications of standard wiring components

8.2.5 To connect the electrical wiring to the indoor unit

FTXP20~35N5V1B9 + ATXP20~35N5V1B9
Split system air conditioners
4P751614-1 – 2023.08
Component
Power supply cable
Interconnection cable
Recommended field fuse
Earth leakage circuit breaker
WARNING
Provide adequate measures to prevent that the unit can be used as a shelter by small
animals. Small animals that make contact with electrical parts can cause
malfunctions, smoke or fire.
NOTICE
Keep the power line and transmission line apart from each other. Transmission
wiring and power supply wiring may cross, but may NOT run parallel.
In order to avoid any electrical interference, the distance between both wirings
should ALWAYS be at least 50 mm.
Electrical work should be carried out in accordance with the installation manual
and the national electrical wiring rules or code of practice.
1 Set the indoor unit on the mounting plate hooks. Use the " " marks as a
guide.
c
a Mounting plate (accessory)
b Interconnection cable
c Wire guide
2 Open the front panel, and then the service cover. Refer to
indoor
unit" [
4
 26].
1-3
Voltage
Phase
Frequency
Wire sizes
a
b
8
Electrical installation
|
220~240 V
1~
50 Hz
Must comply with applicable
legislation
Minimum cable section of
2.5 mm² and applicable for
220~240 V
20 A
Must comply with applicable
legislation
"6.2 Opening the
Installer reference guide
41