10.1 To set a different channel of the indoor unit infrared signal receiver

Installer reference guide
46
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1 Remove the batteries from the user interface.
2 Cut the address jumper.
a Address jumper
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3 Turn the power supply on.
Result: The flap of the indoor unit will open and close to set the reference position.
INFORMATION
In case you could NOT complete the setting in time, turn the power supply off and
wait at least 1 minute before turning the power supply back on.
4 Press simultaneously:
Model
FTXP and ATXP
5 Press:
Model
FTXP and ATXP
6 Select:
Model
FTXP and ATXP
7 Press:
Model
FTXP and ATXP
a
a
Buttons
,
and
Buttons
Symbol
Button
FTXP20~35N5V1B9 + ATXP20~35N5V1B9
Split system air conditioners
4P751614-1 – 2023.08