NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
Page 1
Company Seal or Stamp (Electronic Signature Preferred) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Page 4
VOLTAGE CODE COLOR NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Page 6
99-263 – Thermostat, 24 Volt, Digital, Single Stage., R.G.W.Y.B.O., Battery Power NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
Page 8
Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
Retain these instructions for future reference. GENERAL SAFETY OVERVIEW INFORMATION Use this product only in Mars Air Curtains are the manner intended designed to cover door by the manufacturer. If openings, providing...
Page 10
If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
Page 11
D. Check all field wired components “if supplied” are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G.
Page 12
On average, under normal use conditions, the product should require a Mars reserves the right to change specifications and thorough cleaning once every six (6) months. product design without notice. Such revisions do not...
Document No: HT-IOM Date: 10/20/2023 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the unit’s specific IOM Manual for safety, installation, and startup information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
Page 14
Hot Water and Steam Heated Products The transition section(s) are shipped knocked down and Hot water and steam heated products are certified only are to be field assembled and installed per their for indoor use. Low Profile 2, Standard 2, High Velocity supplemental instructions (FIG.
Page 15
TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
Page 16
TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)
Page 17
Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
Page 18
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
Page 19
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Verification Samples: For each finish product specified, two samples, minimum size 6.25 inches (160 mm) square, representing actual product, color, and patterns. Manufacturer's Certificates: Certify products meet or exceed specified requirements.
Page 21
MARS AIR SYSTEMS, LLC PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
Page 22
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Size: Unheated: 36 inches deep by 28 inches high by width of unit. Electric Heated: 42 inches deep by 28 inches high by width of unit. Hot Water/Steam Heated: Depth 42 inches single row and 44 inches double row by 28 inches high by width of unit plus 10 inches for manifolds.
Page 23
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Type: Filter Only as follows: Filter: Flat bank 2-inch, disposable. Filter: V-bank 2-inch disposable. Filter: V-bank 2-inch aluminum washable. Sound Pressure Level At 10 feet (3 m) From Nozzle: Single Motor/Fan, 7-1/2HP Units: 75 dBA.
Page 24
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Canadian Standards Association (CSA) labeled for US and Canadian application. ANSI Z223/NFPA 54 National Fuel Gas Code. CAN/CGA B149.1 Installation Codes for Natural Gas Burning Appliances and Equipment. Coils: Certified in accordance with AHRI 410.
Page 25
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Mounting: Factory mounted on right hand side of air curtain housing. Mounting: Factory mounted on left hand side of air curtain housing. Motor Control Panels are UL Listed and CSA Approved.
Page 26
Mars WindGuard BD18-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Coordinate with sheet metal flashing as specified in Section 07 62 00. Install joint sealants as specified in Section 07 92 00. Coordinate with electrical power as specified in Section 26 05 00.
Page 27
Belt Drive 18 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Need help?