Download Print this page
Mars BD2296 1I TS Series Manual

Mars BD2296 1I TS Series Manual

Indirect gas fired heated

Advertisement

Quick Links

BD22 Submittal Package
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
www.marsair.com
© Copyright Mars Air Systems, LLC 2014
BD22 Indirect Gas Fired
Heated Series
Belt Drive 22
Industrial Air Curtain
Submittal Package
Submitted by:
Mars Air Systems, LLC
14716 S. Broadway
Gardena, CA 90248
P.O.#
S.Q.
Company
Print Name
Signature
Date
Company Seal or Stamp
(Electronic Signature Preferred)
NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
MARS AIR SYSTEMS, LLC
GARDENA, CA
USA

Advertisement

loading
Need help?

Need help?

Do you have a question about the BD2296 1I TS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mars BD2296 1I TS Series

  • Page 1 Company Seal or Stamp (Electronic Signature Preferred) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 2 CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
  • Page 4 10 HP Motor Unit = 75 dBA, 15 HP Motor Unit = 76 dBA, 20 HP Motor Unit = 77 dBA Furnace Only NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 7 99-277 – Thermostat, 24 Volt, Single Stage, R.W. 99-182 - Cover, Lockable, Clear NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 8 3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
  • Page 9 Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
  • Page 10 Retain these instructions for future reference. GENERAL SAFETY OVERVIEW INFORMATION Use this product only in Mars Air Curtains are the manner intended designed to cover door by the manufacturer. If openings, providing...
  • Page 11 If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
  • Page 12 D. Check all field wired components “if supplied” are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G.
  • Page 13 On average, under normal use conditions, the product should require a Mars reserves the right to change specifications and thorough cleaning once every six (6) months. product design without notice. Such revisions do not...
  • Page 14 TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
  • Page 15 TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450) Applicable Black Motor Wire &...
  • Page 16 Mars is not responsible. The warranty does not cover damages caused by mishandling during transportation. The warranty is voided by removal or alteration of Mars...
  • Page 17 XFC-1 XF/XC SERIES Commercial/Light Commercial Unit Heaters STANDARD FEATURES OPTIONAL FEATURES • Standard or separated combustion all-in-one units • Stainless steel heat exchanger, burners, and/or flue collector • 20-gauge aluminized steel tubular heat exchanger • Two stage and various electronic modulation gas controls •...
  • Page 18 XF/XC SERIES DESCRIPTION ADDITIONAL VENTING FLEXIBILITY The Sterling “XF/XC” Series Convertible Venting Type Tubular The Sterling “XF/XC” unit heater is ETL certified in accordance with Gas-Fired Unit Heater offers a highly efficient, extremely durable categories I and III venting requirements. This certification allows units alternative to the traditional clam shell design.
  • Page 19 Document No: HT-IOM Date: 04/09/2020 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the units specific IOM Manual for safety, installation and start information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
  • Page 20 Steam and Hot Water Coil Heated Products The transition section(s) are shipped knocked down and are to be field assembled and installed per their Steam/Hot Water Coil (coil) heated products must supplemental instructions. (FIG. 6) (Exceptions are be mounted on the inside of the building. The coil(s) for WMI/H and BD series, fully assembled transitions are Low Profile, Standard, High Velocity, Extra Power and provided).
  • Page 21 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
  • Page 22 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
  • Page 23 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Product data and certification letter indicating percentages by weight of post- consumer and pre-consumer recycled content for products having recycled content. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
  • Page 24 PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
  • Page 25 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Housing: Self-contained one-piece type with sufficient strength for mounting from pre- punched mounting holes at both ends to adjacent walls or ceiling without intermediate support. Size: Unheated: 36 inches deep by 28 inches high by width of unit.
  • Page 26 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Air Inlet Grille and Filters: Location: Front. Type: Fixed air intake grille. Expanded Metal: 85% open area. Type: Filter Only as follows: Filter: Flat bank 2-inch, disposable. Filter: V-bank 2-inch disposable.
  • Page 27 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Gas Heaters: Provide field mounted indirect natural gas fired, power vented duct furnace, with aluminized steel heat exchanger and die-formed stainless steel insert burners; manifolds, orifices, flame sensor, and igniter easily removable as an assembly.
  • Page 28 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Motor Control Panels for Gas Heated Units: Recommended for all units whenever a door limit switch is used to automatically start and stop the air curtain. Thermostat is included with optional motor control panel for field installation. Provide motor control panel as follows: Thermostat: Wall-mounted, 24-Volt operation, with heater on/off selection.
  • Page 29 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC INSTALLATION Install air curtains in accordance with approved shop drawings and manufacturer's printed installation instructions. Install air curtains plumb, level, square, true to line, and weathertight, without warp or rack. Anchor air curtains securely in place to supports.
  • Page 30 Mars WindGuard BD22-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SCHEDULES Refer to Air Curtain Schedule appended to this section. END OF SECTION 23 34 33 – 10...
  • Page 31 Belt Drive 22 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.