NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
Page 1
Date Company Seal or Stamp NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Page 4
20 HP Motor Unit = 77 dBA, 25 HP Motor Unit = 78 dBA, 30 HP Motor Unit = 79 dBA, (2) 20 HP Motor Unit = 80 dBA NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Page 6
99-277 – Thermostat, 24 Volt, Single Stage, R.W. 99-182 - Cover, Lockable, Clear NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
Page 8
Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
Retain these instructions for future reference. GENERAL SAFETY OVERVIEW INFORMATION Use this product only in Mars Air Curtains are the manner intended designed to cover door by the manufacturer. If openings, providing...
Page 10
If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
Page 11
D. Check all field wired components “if supplied” are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G.
Page 12
On average, under normal use conditions, the product should require a Mars reserves the right to change specifications and thorough cleaning once every six (6) months. product design without notice. Such revisions do not...
Document No: HT-IOM Date: 04/09/2020 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the units specific IOM Manual for safety, installation and start information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
Page 14
Steam and Hot Water Coil Heated Products The transition section(s) are shipped knocked down and are to be field assembled and installed per their Steam/Hot Water Coil (coil) heated products must supplemental instructions. (FIG. 6) (Exceptions are be mounted on the inside of the building. The coil(s) for WMI/H and BD series, fully assembled transitions are Low Profile, Standard, High Velocity, Extra Power and provided).
Page 15
TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
Page 16
TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450) Applicable Black Motor Wire &...
Page 17
Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
Page 18
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
Page 19
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A879 / A879M -06 – Standard Specification for Steel Sheet, Zinc Coated by the Electrolytic Process for Application Requiring Designation of the Coating Mass on Each Surface.
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Verification Samples: For each finish product specified, two samples, minimum size 6.25 inches (160 mm) square, representing actual product, color, and patterns. Manufacturer's Certificates: Certify products meet or exceed specified requirements.
Page 21
MARS AIR SYSTEMS, LLC PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
Page 22
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Provide rigid mounted base between motor and frame. Factory balanced blower wheel assembly statically and dynamically. Housing: Self-contained one-piece type with sufficient strength for mounting from pre- punched mounting holes at both ends to adjacent walls or ceiling without intermediate support.
Page 23
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Air Speed at Floor: Minimum of 400 fpm (2 m/s) at 3 feet (914 mm) from the floor. Air Inlet Grille and Filters: Location: Front. Type: Fixed air intake grille. Expanded Metal: 85% open area.
Page 24
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Gas Heaters: Provide field mounted indirect natural gas fired, power vented duct furnace, with aluminized steel heat exchanger and die-formed stainless steel insert burners; manifolds, orifices, flame sensor, and igniter easily removable as an assembly.
Page 25
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC with optional motor control panel for field installation. Provide motor control panel as follows: Thermostat: Wall-mounted, 110-Volt operation, with heater on/off selection. Mounting: Shipped loose to be field mounted. Mounting: Factory mounted on right hand side of air curtain housing.
Page 26
Mars WindGuard BD30-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Install air curtains plumb, level, square, true to line, and weathertight, without warp or rack. Anchor air curtains securely in place to supports. Coordinate with sheet metal flashing as specified in Section 07 62 00.
Page 27
Belt Drive 30 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Need help?
Do you have a question about the BD3096-1 TS Series and is the answer not in the manual?
Questions and answers