C.7 Condensate Removal
If you desire to drain condensate from the basepan during unit operation,
this unit is provided with a drain nipple that can be attached to the basepan.
You must provide a 3/8" outside diameter thin-wall plastic or copper tube
which will attach to the drain nipple.
Follow the instructions below:
STEP 1. Find the drain rubber plug on the rear of the basepan and remove it
(see Figure C.7).
STEP 2. Remove the knockout in the lower right side of the rear grille. Slide
the chassis into the WSE SLEEVE so that the drain nipple extends
through the knockout.
STEP 3. Slide the tubing over the drain nipple. If the chassis must be removed
from the sleeve for service, remove the clamped drain hose before
sliding the chassis out of the sleeve.
C.8 Alternate Drain Kits
IDK (Drain Kit)
New construction allowing for condensate drain systems built
within the walls can use the Friedrich Interior Drain Kit (Accessory
#IDK). This kit is designed for installation in the bottom of the sleeve
below the condensate bellows valve (heat/ cool models only).
DK (Drain Kit)
In the event that the outdoor temperature drops below 37 °F, any water
that remains in the chassis basepan is drained into the sleeve pan
on WET and WHT models to prevent freezing. (NOTE: In the cooling
mode of the WCT, WET and WHT models, condensate overflow is
possible in very humid climates). For these particular instances, an
optional drain kit (Accessory #DK) is available for water removal.
C. INSTALLATION OF THE UNIT
Moving Parts Hazard
Do not operate unit out of sleeve
or with front grille removed.
Do not place hands in blower
or fan blade areas.
Failure to do so can result
in serious injury
Moving Parts Hazard
Do not operate unit out of sleeve
or with front grille removed.
Do not place hands in blower
or fan blade areas.
Failure to do so can result
in serious injury
DRAIN
HOSE
Figure C.7
CAUTION
CAUTION
DRAIN
NIPPLE
BASEPAN
SLEEVE
11