Connecting The Stator Winding - Siemens AH 180 Operating Instructions Manual

Three-phase induction motor
Table of Contents

Advertisement

Fixing by means of motor feet
If the motor needs to be aligned, position metal shims underneath the feet in order to prevent
the motor from suffering distortion.
The number of shims should be kept as low as possible i.e. stack as few as possible.
Mounting bolts
To securely mount the motor and reliably transfer the drive torque, use motor mounting bolts
(M12) with the required strength class (8.8) in accordance with ISO 898-1.
Notice
All flange motors must have stable suspension and be supported by means of the end-shield
feet (foot-flange type of construction). When commissioning, make sure that the vibration
values permitted in accordance with DIN ISO 10816 are observed.
Motors that are mounted with their feet on the wall due to their type of construction must be
fixed in position by means of an adequately dimensioned form closure (e.g. by pinning or
using a wall mounting strip).
[ID: 331]

3.4 Connecting the stator winding

Circuit diagram
Details with respect to wiring and connecting the motor winding are laid down in the circuit
diagram enclosed. The circuit diagram is attached to the lid of the terminal box.
SIEMENS AG, 1PH718 A5E00215729A
Operating Instructions - Three-phase induction motor - AH 180
V 2.0
Installation / Assembly
3.4 Connecting the stator winding
3-5