Firmware History; Maintenance - Endress+Hauser RIA15 Operating Instructions Manual

Process indicator
Table of Contents

Advertisement

Maintenance

Diagnostic
Short text
number
S901
Input signal
too small
S902
Input signal
too large
F261
Electronics
module
F283
Memory
content
F431
Factory
calibration
M561
Display
overshoot
22
Remedial action
• Check transmitter output for defect and conformity error
• Check transmitter for incorrect configuration
Diagnostics for the electronics
Replace electronics
• Restart device
• Reset device
• Replace electronics
Replace electronics
Diagnostics for the configuration
Check scaling
8.3

Firmware history

Release
The firmware version on the nameplate and in the Operating Instructions indicates the
device release: XX.YY.ZZ (example 1.02.01).
XX
YY
ZZ
Date
Firmware
version
11/2012
ISU00XA:
1.00.01
03/2013
ISU00XA:
1.01.00
07/2013
ISU00XA:
1.02.00
11/2014
ISU00XA:
1.03.00
05/2016
ISU00XA:
1.04.00
07/2019
ISU00XA:
1.06.xx
9
Maintenance
No special maintenance work is required for the device.
Status signal
S
S
F
F
F
M
Change to main version
No longer compatible The device and Operating Instructions change.
Change to functions and operation
Compatible The Operating Instructions change.
Fixes and internal changes
No changes to the Operating Instructions
Software changes
Original software
HART® option, only relevant for HART®
version
HART® level measurement, only relevant for
HART® version
New EXP1-EXP4 parameter for HART®
option, only relevant for HART® version
New menus and parameters in "FMR20 basic
commissioning", relevant only to HART®
version
Display of the mA value in 4-20 mA mode
via + or - key held down
RIA15
Diagnostic
Priority
behavior
Warning
4
Warning
5
Alarm
1
Alarm
2
Alarm
3
Warning
7
Documentation
BA01073K/09/EN/02.13
BA01073K/09/EN/03.13
BA01073K/09/EN/04.13
BA01073K/09/EN/05.14
BA01073K/09/EN/06.15
BA01073K/09/EN/07.23
Endress+Hauser