7.5 Functions in 3-channel DMX mode................... 36 7.6 Functions in 4-channel DMX mode................... 36 7.7 Functions in 5-channel DMX mode................... 37 7.8 Functions in 6-channel DMX mode................... 37 7.9 Functions in 10-channel DMX mode..................38 Technical specifications........................42 Z120M Par 64 LED RGBW 120W LED PAR...
Page 4
Table of contents Plug and connection assignments....................44 Troubleshooting............................45 Cleaning............................... 48 Protecting the environment......................49 Z120M Par 64 LED RGBW 120W LED PAR...
1.1 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this document. Z120M Par 64 LED RGBW 120W LED PAR...
Page 7
Warning signs Type of danger Warning – high-voltage. Warning – dangerous optical radiation. Warning – suspended load. Z120M Par 64 LED RGBW 120W LED PAR...
Page 8
General information Warning signs Type of danger Warning – danger zone. Z120M Par 64 LED RGBW 120W LED PAR...
Always dispose of packaging material properly when it is not in use. Never allow children to use the device without supervi‐ sion. Keep small parts away from children and make sure that the device does not shed any small parts (such knobs) that children could play with. Z120M Par 64 LED RGBW 120W LED PAR...
Page 10
The device emits flashing lights (strobe effects). Flashing lights can trigger epileptic fits in specific people. If you are at risk of epi‐ lepsy, avoid spending longer periods of time subjected to flashing lights and looking into strobing light. Z120M Par 64 LED RGBW 120W LED PAR...
Page 11
Only operate the device from professionally installed mains sockets that are protected by a residual current circuit breaker (FI). As a precaution, disconnect the device from the power grid when storms are approaching or it the device will not be used for a longer period. Z120M Par 64 LED RGBW 120W LED PAR...
Page 12
Using fuses of a different type than compatible with the device may cause a fire and seriously damage the device. Only use fuses of the same type. Observe the labelling on the device casing and the information in the "Technical data” chapter. Z120M Par 64 LED RGBW 120W LED PAR...
For technological reasons, the light output of LEDs decreases over their lifetime. This effect increases with higher operating temperature. You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowest possible brightness. Z120M Par 64 LED RGBW 120W LED PAR...
When installing and operating, make sure to follow the standards and regulations that apply in your country. Always secure the device with a secondary safety attachment, such as a safety cable or a safety chain. Z120M Par 64 LED RGBW 120W LED PAR...
Page 15
If the device is mounted on an unsuitable stand, there is a risk that the stand will fall over and cause damage. Only use stands whose maximum bearing capacity is at least as high as the weight of the device. Always ensure that the stand is stable. Z120M Par 64 LED RGBW 120W LED PAR...
Page 16
The safety cable must be attached to the safety eyelet. Please note that this device must not be connected to a dimmer. Z120M Par 64 LED RGBW 120W LED PAR...
(110 Ω, ¼ W). DMX indicator When the device and the DMX controller are operational, the DMX indicator in the display shows that a DMX signal is being received on the input. Z120M Par 64 LED RGBW 120W LED PAR...
Page 18
DMX output of the master unit to the DMX input of the first slave unit. Then connect the DMX output of the first slave unit to the DMX input of the second slave unit and so on. Z120M Par 64 LED RGBW 120W LED PAR...
Connections and controls Connections and controls & ö PUSH Z120M Par 64 LED RGBW 120W LED PAR...
Page 20
8 [POWER OUT] | Lockable output socket (Power Twist IP65) for the power supply of further units 9 [POWER IN] | Lockable input socket (Power Twist) for power supply 10 Fuse holder Z120M Par 64 LED RGBW 120W LED PAR...
If you do not press any button for about 8 seconds, the display will turn off. The set values are retained even when the device is disconnected from the mains power supply. Z120M Par 64 LED RGBW 120W LED PAR...
Page 22
Press [ENTER] to accept the selection. This setting is only relevant when the device is controlled via DMX. When the DMX mode is active, a dot flashes in the second digit of the display. Z120M Par 64 LED RGBW 120W LED PAR...
Page 23
‘DInd’ . Confirm with [ENTER]. to select the desired dimmer setting. Press [ENTER] to accept the selection. Display Meaning ‘stdA’ Standard setting ‘st9e’ Stage setting ‘tu’ TV setting ‘ArAL’ Building setting ‘thAL’ Theatre setting Z120M Par 64 LED RGBW 120W LED PAR...
Page 24
Press [ENTER] to accept the selection. Display Meaning ‘Linn’ Linear ‘Inue’ Inverse Square ‘Suar’ Square ‘Scur’ S-curve Linear Square Inv Square S-Type 100 % 100 % 100 % 100 % ö ö ö ö Z120M Par 64 LED RGBW 120W LED PAR...
Page 25
900 Hz and 25 kHz (display shows ‘900’ … ‘25t’ ). Press [ENTER] to accept the selection. Display Display ‘900’ ‘2500’ ‘1000’ ‘4000’ ‘1100’ ‘5000’ ‘1200’ ‘10t’ ‘1300’ ‘15t’ ‘1400’ ‘20t’ ‘1500’ ‘25t’ Z120M Par 64 LED RGBW 120W LED PAR...
Page 26
ð The device is now working in slave mode, i.e. it will exactly copy the movement of the controlling master device, correct wiring provided. To exit slave mode, select ‘Mast’ and confirm with [ENTER]. This setting is only relevant if the device is not controlled via DMX. Z120M Par 64 LED RGBW 120W LED PAR...
Page 27
DMX controller fails. Press [ENTER] to accept the selection. Display Meaning ‘blac’ Spotlight turns off. ‘hold’ Last effect is being held. ‘auto’ Automatic mode is activated. ‘soun’ Sound control is activated. Z120M Par 64 LED RGBW 120W LED PAR...
Page 28
Press [ENTER] repeatedly to activate the desired sub menu. to select a value between ‘CCT1’ and ‘CCT9’ for the sub menu ‘CCT’ , or use to select a value between ‘Cor1’ and ‘Cor9’ for the sub menu ‘Clor’ . Z120M Par 64 LED RGBW 120W LED PAR...
Page 29
‘000’ and ‘255’ to adjust dimmer intensity, strobe frequency or colour intensity. Press [ENTER] to accept the selection. Anzeige Bedeutung ‘Dimmer’ Dimmer intensity ‘Strobe’ Strobe effect ‘Red’ ‘Green’ Green ‘ Blue’ Blue ‘White’ White Z120M Par 64 LED RGBW 120W LED PAR...
Page 30
Rotating the Display Press repeatedly until the display shows ‘dISP’ . Confirm with [ENTER]. to choose between ‘On’ (display rotated by 180 °) and ‘oFF’ (display not rotated). Press [ENTER] to accept the selection. Z120M Par 64 LED RGBW 120W LED PAR...
Page 31
ð The display shows the current software version used by the device. Press [ENTER]. ð The menu is closed. Reset Press [MENU] and then repeatedly until the display shows ‘dEFA’ . Confirm with [ENTER]. ð The device is reset to the default settings. Z120M Par 64 LED RGBW 120W LED PAR...
Linn SL 1 blac Sh _ 2 A512 stge Inue 1000 Mast hold Sh _ 3 Suar 1100 auto aral Scur 1200 soun thal 1300 10Ch 1400 1500 2500 4000 5000 Z120M Par 64 LED RGBW 120W LED PAR...
Dimmer xxxH ux.x S099 CCT9 strobe Clor Cor1 Cor9 green blue white 7.4 Functions in 2-channel DMX mode Channel Value Function 000…005 No function 006…017 Colour macro red 018…029 Colour macro amber Z120M Par 64 LED RGBW 120W LED PAR...
Page 34
Colour macro crimson red 138…149 Colour macro pink 150…161 Colour macro warm white 162…173 Colour macro white 174…185 Colour macro cold white 186…220 Colour change, increasing speed 221…255 Colour-fade effect, increasing speed 000…035 No function Z120M Par 64 LED RGBW 120W LED PAR...
Page 35
Colour temperature macro 4500 K 156…175 Colour temperature macro 5000 K 176…195 Colour temperature macro 5500 K 196…215 Colour temperature macro 6000 K 216…235 Colour temperature macro 6500 K 236…255 Colour temperature macro 7200 K Z120M Par 64 LED RGBW 120W LED PAR...
7.6 Functions in 4-channel DMX mode Channel Value Function 000…255 Intensity red (0 %…100 %) 000…255 Intensity green (0 %…100 %) 000…255 Intensity blue (0 %…100 %) 000…255 Intensity white (0 %…100 %) Z120M Par 64 LED RGBW 120W LED PAR...
7.8 Functions in 6-channel DMX mode Channel Value Function 000…255 Master dimmer (0 %…100 %) 000…015 No function (blackout) 016…030 Shutter open 031…090 Strobe ramp up effect, increasing speed 091…105 Shutter open Z120M Par 64 LED RGBW 120W LED PAR...
Intensity blue (0 %…100 %) 000…255 Intensity white (0 %…100 %) 7.9 Functions in 10-channel DMX mode Channel Value Function 000…255 Master dimmer (0 %…100 %) 000…015 No function (blackout) 016…030 Shutter open Z120M Par 64 LED RGBW 120W LED PAR...
Page 39
Intensity blue (0 %…100 %) 000…255 Intensity white (0 %…100 %) 000…005 No function 006…017 Colour macro red 018…029 Colour macro amber 030…041 Colour macro warm yellow 042…053 Colour macro yellow 054…065 Colour macro green Z120M Par 64 LED RGBW 120W LED PAR...
Page 40
Colour macro cold white 186…220 Colour change, increasing speed 211…255 Colour-fade effect, increasing speed 000…035 No function 036…055 Colour temperature macro 2800 K 056…075 Colour temperature macro 3000 K 076…095 Colour temperature macro 3200 K Z120M Par 64 LED RGBW 120W LED PAR...
Page 41
No function 016…095 Automatic show 1: Colour change 096…175 Automatic show 2: Strobe effect colour 176…255 Automatic show 3: Colour-fade effect 000…250 Sound control off, automatic program speed, increasing 251…255 Sound control on Z120M Par 64 LED RGBW 120W LED PAR...
XLR chassis socket, 3-pin Output connections Voltage supply Lockable output socket (Power Twist) DMX control XLR chassis socket, 3-pin Power consumption 125 W Operating supply voltage 100 - 240 V 50/60 Hz Z120M Par 64 LED RGBW 120W LED PAR...
Page 43
Dimensions (W × H × D) 224 mm × 275 mm × 491 mm Weight 3.24 kg Ambient conditions Temperature range 0 °C…40 °C Relative humidity 20 %…80 % (non-condensing) Z120M Par 64 LED RGBW 120W LED PAR...
The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suitable XLR plug. Configuration Ground, shielding Signal inverted (DMX–, ‘cold signal’) Signal (DMX+, ‘hot signal’) Z120M Par 64 LED RGBW 120W LED PAR...
Use special DMX cables for the wiring instead of normal microphone cables. In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting: Z120M Par 64 LED RGBW 120W LED PAR...
Page 46
4. Try using another DMX controller. 5. Check whether the DMX cables run near or parallel to high-voltage cables that may cause damage or interfer‐ ence to a DMX interface circuit. Z120M Par 64 LED RGBW 120W LED PAR...
Page 47
Troubleshooting If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de. Z120M Par 64 LED RGBW 120W LED PAR...
Before cleaning, switch off the device and disconnect mains-operated devices from the mains. Only use pH-neutral, solvent-free and non-abrasive cleaning agents. Clean the unit with a slightly damp lint-free cloth. Z120M Par 64 LED RGBW 120W LED PAR...
Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility. Z120M Par 64 LED RGBW 120W LED PAR...
Page 50
Notes Z120M Par 64 LED RGBW 120W LED PAR...
Need help?
Do you have a question about the Z120M Par 64 LED RGBW 120W and is the answer not in the manual?
Questions and answers