We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
PNOZ e8.1p Introduction Validity of documentation This documentation is valid for the product PNOZ e8.1p. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
Safety Intended use The PNOZ e8.1p is the evaluation device for safe line inspection with PLID d1. As the eval- uation device for PLID d1, the PNOZ e8.1p achieves PL d (Cat. 2) in accordance with EN ISO 13849-1 and SIL CL 2 in accordance with EN IEC 62061.
Please make sure you shut down the supply voltage or open the input circuit (e.g. oper- ate the E-STOP pushbutton) when performing maintenance work (e.g. when replacing contactors), otherwise the unit might switch on unexpectedly in the case of a wiring error. Operating Manual PNOZ e8.1p 1002226-EN-09...
The safety device remains effective in the case of a component failure. The safety outputs are tested periodically using an off-test. Block diagram/terminal configuration S32 S42 Feed- PLIDdys Input Input Start Input back PNOZ e8.1p & Power Test Diag- Pulse nostic Output Operating Manual PNOZ e8.1p 1002226-EN-09...
1,8 (see Faults – Interference [ 17]). It will not be possible to switch the unit back on until the error has been rectified and the supply voltage has been switched off and then on again. Operating Manual PNOZ e8.1p 1002226-EN-09...
When installed vertically: Secure the unit by using a fixing element (e.g. retaining bracket or end angle). NOTICE If you are connecting several units logically, please note the guidelines in the section entitled Logic connection between several units [ 15]. Operating Manual PNOZ e8.1p | 10 1002226-EN-09...
(SELV, PELV) in accordance with VDE 0100, Part 410. Terminal Y5 is provided for Pilz-internal diagnostic purposes. Where one line is to be monitored, only use one PNOZ e8.1p and one PLID d1. Route the line so that it is protected.
Y7 with a bridge, depending on the required start behaviour. NOTICE With automatic start The unit starts up automatically when the safeguard is reset, e.g. when the E-STOP pushbutton is released. Use external circuit measures to prevent an unexpected restart. Operating Manual PNOZ e8.1p | 13 1002226-EN-09...
The unit with the lowest SIL/PL value determines the SIL/PL value of the entire circuit. PNOZ e1p, PNOZ e8.1p: These units do not have logic inputs. Their safety outputs can be used to logically link the units to the logic inputs of other PNOZelog units or to the cas- cading inputs from PNOZmulti units.
Status indicators POWER Supply voltage is present, operating mode is detected. POWER Initialisation phase CH.1 There is a high signal at safety output 14. CH.2 There is a high signal at safety output 24. Operating Manual PNOZ e8.1p | 16 1002226-EN-09...
The number of LED flashes corresponds to a digit in the error code. The error code can consist of up to 4 digits. The digits are separated by a longer period without flash- ing. The entire sequence is constantly repeated. INFORMATION Error code 0: 16 flashes Operating Manual PNOZ e8.1p | 17 1002226-EN-09...
Page 18
LED CH.1 or CH.2 flashes 3 times, short Pause Once for one second Pause 3 times, for one second each Error code 1: LED CH.1 or CH.2 flashes 3 times, short Pause Once for one second Operating Manual PNOZ e8.1p | 18 1002226-EN-09...
Page 19
The table below shows the relationship between the number of flashes and the error code. The key to the error codes is described in the Error coding table. Number of flashes Decimal er- ror code Operating Manual PNOZ e8.1p | 19 1002226-EN-09...
Page 20
– 13x long – 3x short 1, 4 3x short – 1x long Operating mode changed during Check wiring for the operating mode – 4x long – 3x short operation and rectify fault Operating Manual PNOZ e8.1p | 20 1002226-EN-09...
Page 21
+24 VDC 2, 0, 3 3x short – 2x long <19.2 VDC Keep within the supply voltage range – 16x long – 3x long of 19.2 ... 30 VDC – 3x short Operating Manual PNOZ e8.1p | 21 1002226-EN-09...
24 V 24 V Current at Input circuit DC 5 mA 5 mA Start circuit DC 5 mA 5 mA Feedback loop DC 5 mA 5 mA Logic input 5 mA 5 mA Operating Manual PNOZ e8.1p | 22 1002226-EN-09...
Page 23
Logic inputs typ. 150 ms 150 ms Logic inputs max. 200 ms 200 ms Response time tr semiconductor outputs Via input circuit max. 35 ms 35 ms Via logic input max. 50 ms 50 ms Operating Manual PNOZ e8.1p | 23 1002226-EN-09...
Page 24
PPO UL 94 V0 PPO UL 94 V0 Front ABS UL 94 V0 ABS UL 94 V0 PPO UL 94 V0 PPO UL 94 V0 Connection type Screw terminal Spring-loaded terminal Mounting type plug-in – Operating Manual PNOZ e8.1p | 24 1002226-EN-09...
Page 25
8 mm Dimensions Height 94 mm 101 mm Width 22,5 mm 22,5 mm Depth 121 mm 121 mm Weight 130 g 125 g Where standards are undated, the 2020-07 latest editions shall apply. Operating Manual PNOZ e8.1p | 25 1002226-EN-09...
A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PNOZ e8.1p | 26 1002226-EN-09...
Page 27
Product type Features Order no. Terminal block filter 1 Terminal block with filter for 3-10 kOhm load range 774195 Terminal block filter 2 Terminal block with filter for 10-30 kOhm load range 774196 Operating Manual PNOZ e8.1p | 27 1002226-EN-09...
Page 28
This product/these products meet the requirements of the directive 2006/42/EC for ma- chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany UKCA-Declaration of Conformity This product(s) complies with following UK legislation: Supply of Machinery (Safety) Regu- lation 2008.
Page 29
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...