Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
PLID d1 Introduction Validity of documentation This documentation is valid for the product PLID d1. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
Short circuit, Short between contacts, Open circuit. The PLID d1 may only be used in conjunction with the evaluation device PNOZ e8.1p. The following is deemed improper use in particular Any component, technical or electrical modification to the product, Use of the product outside the areas described in this manual,...
Block diagram Function description The PLID d1 sends a test pulse signal via a contact (E-STOP pushbutton or start button) to the evaluation device PNOZ e8.1p. If the line is error-free, the input circuits are closed and the contact is closed (E-STOP pushbutton or start button) a valid signal is present at the in- put S36 of the PNOZ e8.1p.
The cable length between PLID d1 and contact (E-STOP pushbutton or start button) should be as short as possible. Where one line is to be monitored, only use one PLID d1 and one evaluation device. Route the line so that it is protected.
A short circuit on the pushbutton or on the supply line to the pushbut- ton is not monitored! Use appropriate measures to prevent a short circuit on the pushbutton. Dimensions in mm PLID d1 (screw terminals) PLID d1 C (spring-loaded terminals) Operating Manual PLID d1 1002227-EN-04...