1.15 MAXIMUM FLUE LENGTH
Type
Ø 60/100mm
Ø 80/125mm
Ø 80/80mm
Ø 50 flexible
Ø 60mm rigid
Ø 80mm rigid
Ø 80 flexible
Ø 50 flexible
Ø 60mm rigid
Ø 80mm rigid
Ø 80 flexible
Note: Installation C10-C12 type-approved only with G20 gas.
Type
Ø 60/100mm
Ø 80/125mm
Ø 80/80mm
Ø 50 flexible
Ø 60mm rigid
Ø 80mm rigid
Ø 80 flexible
Ø 50 flexible
Ø 60mm rigid
Ø 80mm rigid
Ø 80 flexible
Note: Installation C10-C12 type-approved only with G20 gas.
The values indicated in the table are the maximum available lengths.
Adjustment of the maximum boiler speed depending on the length of the actual pipes installed must refer to the Table in Par.
3.8.
The flue parameter (heat output) must be calibrated by the maintenance technician at initial testing.
36
C13 (horizontal+curve)
C33 (vertical)
C13 (horizontal+elbow) C33 (vertical)
C(10)3 - C(12)3
C43 - C53 - C83 (split)
C(10)3 - C(12)3
B23 - B23p - B33 - B53 - B53p
C53
Split duct 80/80 from boiler to connection in flue
C93
Concentric 60/100 or 80/125 from boiler to flue
C13 (horizontal+curve)
C33 (vertical)
C13 (horizontal+elbow) C33 (vertical)
C(10)3 - C(12)3
C43 - C53 - C83 (split)
C(10)3 - C(12)3
B23 - B23p - B33 - B53 - B53p
C53
Split duct 80/80 from boiler to connection in flue
C93
Concentric 60/100 or 80/125 from boiler to flue
Installation
Installation
VICTRIX TERA V2 24 PLUS EU
L = Maximum length (m)
13
14,5
35
10
35
15
30
20
25
35
30
20
25
35
30
VICTRIX TERA V2 35 PLUS EU
L = Maximum length (m)
13
14,5
35
10
35
15
30
13
25
35
30
13
25
35
30