GENMAX GM4600iAEFIC User Manual

GENMAX GM4600iAEFIC User Manual

Inverter generator

Advertisement

Quick Links

INVERTER GENERATOR
USER'S MANUAL
GM4600iAEFIC
3800 Running Watts | 4600 Peak Watts
WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety. Operation,
maintenance and storage of this product. Before use, read carefully and
understand all cautions, warnings, instructions and product labels. Failure to do
so could result in serious personal injury and/or property damage.
R
GENMAX GENERATOR

Advertisement

Table of Contents
loading

Summary of Contents for GENMAX GM4600iAEFIC

  • Page 1 GENMAX GENERATOR INVERTER GENERATOR USER'S MANUAL GM4600iAEFIC 3800 Running Watts | 4600 Peak Watts WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety. Operation, maintenance and storage of this product. Before use, read carefully and understand all cautions, warnings, instructions and product labels.
  • Page 2 DISCLAIMERS: All information, illustrations and specifications in this manual are based on the latest information available at the time of publishing. The illustrations used in this manual are intended as representative reference views only. Moreover, because of our continuous product improvement policy, we may modify information, illustrations and/or specifications to explain and/or exemplify a product, service or maintenance improvement.
  • Page 3 DESCRIPTION OF FITTINGS Spark Plug Socket Wrench Dual-Purpose Screwdriver Funnel Phillips and slot blade Used in spark plug maintenance, screwdriver used for generator It's used to oil the generator. inspection, and installation. maintenance. Cigarette Lighter to USB-C&A Remote Control Key 450ml 10W30 Oil Adapter Convert the cigarette lighter...
  • Page 4: Limited Warranty

    2. WHO GIVES THIS WARRANTY (WARRANTOR): CHONGQING DINKING POWER MACHINERY CO., LTD 3. WHO RECEIVES THIS WARRANTY(PURCHASER):The original purchaser (other than for purposes of resale) of the Genmax's inverter. 4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any portable generator supplied or manufactured by Warrantor.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS LIMITED WARRANTY SAFETY WARNING SAFETY INSTRUCTIONS NAMES OF COMPONENTS CONTROL FUNCTIONS PREPARATIONS 1.Fuel............................11 2.Oil............................11 3.Pre-operation Inspection.......................12 STARTING UP THE GENERATOR SHUTTING DOWN THE GENERATOR USING THE GENERATOR 1.Service Environment of the Generator..................16 2.Generator Wiring........................16 3.Generator Grounding........................17 4.Parallel and Series Operation....................18 5.Battery Charging........................19 SERVICE AND MAINTENANCE 1.Spark Plug Inspection......................21...
  • Page 6: Safety Warning

    SAFETY WARNING Personal and property safeties of you and others are very vital. Please read the Safety Warning in the User's Manual and the decals of the generator set carefully.The Safety Warning can alert you to those potential hazards that could harm you and others. In front of each Safety Warning, there is one of four words "DANGER"...
  • Page 7: Safety Instructions

    SAFETY INSTRUCTIONS Before operating the generator, it will help you avoid accidents to read and understand the Manual and familiarize yourself with the safe operation procedures of the generator. Please do not use in humid Please do not use indoors environment Please do not connect it to Please do not smoke when refueling...
  • Page 8 SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS...
  • Page 9: Names Of Components

    NAMES OF COMPONENTS ① Fuel Tank Cap: Open the fuel tank cap and fill with ⑧ Muffler: Avoid contact until the engine is cooled proper amount of gasoline. down. The spark arrestor prevents sparks from exiting the muffler. It must be removed for servicing. ②...
  • Page 10: Control Functions

    "OFF" position, generators with special parallel kit GM6000SPK sold by which can prevent the battery from running out. GENMAX. The connector sockets is only used to connect two inverter generators. They can not used for AC power output.
  • Page 11 CONTROL FUNCTIONS DIGITAL DISPLAY CENTER ① : Represents single run time, goes from 0 ④ VOLTAGE: Voltage display. at each startup. ⑤ FREQUENCY: Frequency display. ② : Represents total operation time of the ⑥ LOAD: Load power display. generator. (Tip: The total operation time shall start to ⑦...
  • Page 12: Preparations

    PREPARATIONS Fuel DANGER • Fuel is flammable and toxic, please read the Safety Instruction carefully before refueling; • Do not fuel too full, otherwise fuel will spill after fuel tank is warmed; • After refueling, confirm that the fuel tank cap has been tightened. ATTENTION •...
  • Page 13: Pre-Operation Inspection

    PREPARATIONS Pre-use Inspection WARNING Even if the generator is not in service, its important component may suddenly fails. Before the generator is started up, if any of following components is unable to work properly, please inspect and repair carefully. Tip: The condition of the generator shall be inspected before using every time. Pre-operation inspection Project Possible Causes...
  • Page 14: Starting Up The Generator

    STARTING UP THE GENERATOR Remove the load from all output ends; Connect battery line before first use: 1. Loosen the knob on the right cover and remove the cover; 2. Connect the positive and negative electrodes of the battery. Tip: Connect the same color wires together, do not connect the wrong positive and negative wires.
  • Page 15 STARTING UP THE GENERATOR Remote Control Pairing 1. Long press the start button for more than 5 seconds until the button red indicator is on; 2. Press any key on the remote control; 3. The red indicator of the start button will blink two or three times and then turns off, Remote start pairing is successful.
  • Page 16: Shutting Down The Generator

    SHUTTING DOWN THE GENERATOR Unplug the power cord; Select Stop Mode: a. START/STOP Button Stop: Press the one- click start button to turn off the generator. b. Remote Stop: Press the "OFF" button on the remote control to turn off the generator. Move the Main Switch to "OFF".
  • Page 17: Using The Generator

    USING THE GENERATOR Service Environment of the Generator • Applicable temperature: -5°C~ 40°C; • Applicable humidity: below 95%; • Applicable altitude: regions below 1,500 m (It shall be used by reducing power in regions above 1,000 m). Standard atmospheric condition •...
  • Page 18: Generator Grounding

    USING THE GENERATOR Connection of AC power WARNING All electrical equipment shall be disconnected before inserting the plug. ATTENTION • Make sure that all electrical equipment, including wires and plugs, are in good condition before connecting to the generator; • Make sure that all loads driven by the generator are within rated load range; •...
  • Page 19: Parallel And Series Operation

    To increase AC power output, the connector sockets are used to connect the two same type generators with special parallel kit GM6000SPK sold by GENMAX. The connector sockets is only used to connect two inverter generators. They can not used for AC power output. The special paralleling kit GM6000SPK shall be purchased separately, and they shall be approved by certification body.
  • Page 20: Battery Charging

    USING THE GENERATOR Battery Charging The battery storage time is generally about 6 months. If the generator is not used for a long time, the battery will run out of power. At this time, the battery should be charged. Replace the battery if it is damaged or fails to charge.
  • Page 21: Service And Maintenance

    SERVICE AND MAINTENANCE Good maintenance and service is the best guarantee for safe, economical and zero-failure operation. It also contributes to environmental protection. In order to keep the generator in good condition, you must inspect and maintain it regularly. The maintenance schedule is as follows: Then every three Maintenance cycle...
  • Page 22: Spark Plug Inspection

    SERVICE AND MAINTENANCE WARNING Please shut down the engine first before performing any maintenance. The engine shall be placed in a horizontal position. In order to prevent the engine from starting up, separate spark plug cap shall be separated from spark plug. Do not use it indoors or use it in a tunnel, cave or other places ventilated poorly.
  • Page 23: Replacement Of Oil

    SERVICE AND MAINTENANCE Install the spark plugs in reverse order of removal. Spark plug torque: 14±1N.m(123.9±8.8in-lb) Tip: If there is no torque wrench when installing the spark plug, a better estimation method is to screw it 1/4-1/2 turns by force after screwing it in place, but the spark plug shall be screwed to specified torque as soon as possible. Replacement of Oil WARNING Do not drain the oil immediately after turning off the generator.
  • Page 24: Air Filter

    SERVICE AND MAINTENANCE Air Filter Dirty air cleaner may prevent air from flowing into the carburetor. In order to prevent failure of the carburetor, please maintain air cleaner regularly. If being used in a dusty environment, it shall be maintained frequently. Loosen the knob on the right cover counterclockwise and remove the right cover.
  • Page 25: Fuel Filter Screen

    SERVICE AND MAINTENANCE Fuel Filter Screen WARNING Be sure not to open fuel tank of the generator in a place where smoking or with flame. 1. Remove fuel tank cap and fuel tank filter screen. 2. Clean fuel tank filter screen with gasoline. 3.
  • Page 26: Storage And Transport

    STORAGE AND TRANSPORT Generator Storage If it is stored long-term, in order to prevent aging, you shall take some storage measures. Shut down generator. Open fuel tank cap, to take out fuel filter screen. Pump all fuel in fuel tank into special fuel tank, and then reassemble fuel tank cap back.
  • Page 27: Troubleshooting

    TROUBLESHOOTING...
  • Page 28 TROUBLESHOOTING...
  • Page 29: Technical Parameters

    TECHNICAL PARAMETERS Item GM4600iAEFIC Rated Power (kW) Max. Power (kW) 165F/P-EFI Engine Model Input valve:0.03~0.08mm, Output valve:0.03~0.08mm Valve Clearance 65x48 Stroke x Bore (mm) Engine Type 4-stroke Displacement (cc) Gas Distribution Mode Cooling Mode Forced cooling wind Rated Speed (RPM)
  • Page 30: Circuit Diagram

    CIRCUIT DIAGRAM GM4600iAEFIC SCHEMATICS...
  • Page 31: Choosinga Generator

    CHOOSING A GENERATOR...
  • Page 32 In production management, based on orderly, efficient, scientific principles. trying to do as better as possible in product design, development, production, inspection, etc. to make our production can keep orderly. And will continue to make improvement to make sure that keep the competitiveness.

Table of Contents