Summary of Contents for GENMAX GM9000iE

  • Page 1 GENMAX GENERATOR INVERTER GENERATOR USER'S MANUAL GM9000iE GM9000iED/GM9000iEDC Portable Inverter Generator Portable Inverter Generator 7600 Running Watts | 9000 Peak Watts 7600(GAS.)/7200(LPG) Running Watts | 9000(GAS.)/8550(LPG) Peak Watts WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety. Operation, maintenance and storage of this product.
  • Page 2 DISCLAIMERS: All information, illustrations and specifications in this manual are based on the latest information available at the time of publishing. The illustrations used in this manual are intended as representative reference views only. Moreover, because of our continuous product improvement policy, we may modify information, illustrations and/or specifications to explain and/or exemplify a product, service or maintenance improvement.
  • Page 3: Limited Warranty

    3. WHO RECEIVES THIS WARRANTY(PURCHASER):The original purchaser (other than for purposes of resale) of the Genmax's inverter.4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any portable generator supplied or manufactured by Warrantor.5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects on material and workmanship which occur within the durat ion of the warranty period.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS LIMITED WARRANTY SAFETY WARNING SAFETY INSTRUCTIONS NAMES OF COMPONENTS CONTROL FUNCTIONS PREPARATIONS 1.Fuel............................11 2.Oil...............................11 3.Pre-operation inspection......................12 STARTING UP THE GENERATOR SHUTTING DOWN THE GENERATOR USING THE GENERATOR 1.Service environment of the generator..................17 2.Generator wiring........................17 3.Generator grounding.........................18 SERVICE AND MAINTENANCE 1.Spark plug inspection.......................20 2.Adjustment of the carburetor.....................21 3.Replacement of oil........................21...
  • Page 5: Safety Warning

    SAFETY WARNING Personal and property safeties of you and others are very vital. Please read the Safety Warning in the User's Manual and the decals of the generator set carefully.The Safety Warning can alert you to those potential hazards that could harm you and others. In front of each Safety Warning, there is one of four words "DANGER"...
  • Page 6: Safety Instructions

    SAFETY INSTRUCTIONS Before operating the generator, it will help you avoid accidents to read and understand the Manual and familiarize yourself with the safe operation procedures of the generator. Please do not use in humid Please do not use indoors environment Please do not connect it to Please do not smoke when refueling...
  • Page 7 SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS...
  • Page 8: Names Of Components

    NAMES OF COMPONENTS LPG Port(GM9000iED/GM9000iEDC only) Fuel tank Control panel Drag rod Left enclosure Start handle Muffler Wheel Right enclosure...
  • Page 9: Control Functions

    CONTROL FUNCTIONS CONTROL PANEL FEATURES GM9000iE ① 120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R): ⑪ One Push Start: Press this button, the engine can The outlet is capable of carrying a maximum of 20 start and stop. amps. ⑫ Voltage Selector: Switch between 120V and 240V ②...
  • Page 10 CONTROL FUNCTIONS CONTROL PANEL FEATURES GM9000iED/GM9000iEDC ① 120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R): ⑫ One Push Start: Press this button, the engine can The outlet is capable of carrying a maximum of 20 start and stop. amps. ⑬ Voltage Selector: Switch between 120V and 240V ②...
  • Page 11 CONTROL FUNCTIONS DIGITAL DISPLAY CENTER ① HOURS: Represents single run time, goes from 0 ⑤ LOAD: Load power display. at each startup. ⑥ POWER: Green light means normal operation. ② HOURS: Represents total operation time of the ⑦ OVERLOAD: Red light means the machine generator.
  • Page 12: Preparations

    PREPARATIONS Fuel DANGER • Fuel is flammable and toxic, please read the Safety Instruction carefully before refueling; • Do not fuel too full, otherwise fuel will spill after fuel tank is warmed; • After refueling, confirm that the fuel tank cap has been tightened. ATTENTION •...
  • Page 13: Pre-Operation Inspection

    PREPARATIONS Pre-use Inspection WARNING Even if the generator is not in service, its important component may suddenly fails. Before the generator is started up, if any of following components is unable to work properly, please inspect and repair carefully. Tip: The condition of the generator shall be inspected before using every time. Pre-operation inspection Fuel •...
  • Page 14: Starting Up The Generator

    STARTING UP THE GENERATOR GM9000iE Startup Procedure Remove the load from all output ends; Connect battery line before first use: 1. Remove the left panel cover; 2. Connect the positive and negative electrodes of the battery. Turn the fuel switch clockwise to "ON";...
  • Page 15 STARTING UP THE GENERATOR GM9000iED/GM9000iEDC Startup Procedure Remove the load from all output ends; Connect battery line before first use: 1. Remove the left panel cover; 2. Connect the positive and negative electrodes of the battery. Select the Fuel: a. Gasoline: Turn the fuel source switch to gasoline. b.
  • Page 16 STARTING UP THE GENERATOR Select Boot Mode: a. Hand Starting: Pull the starting handle to start the generator. b. One Button to Start: Press the one-click start button to start the generator. c. Remote Start: Press the "START" button on the remote control to start the generator. Plug in after started.
  • Page 17: Shutting Down The Generator

    SHUTTING DOWN THE GENERATOR Unplug the power cord; Select Stop Mode: a. One Button to Start: Press the one-click start button to turn off the generator. b. Remote Start: Press the "STOP" button on the remote control to turn off the generator. Press the main switch to "OFF";...
  • Page 18: Using The Generator

    USING THE GENERATOR Service environment of the generator • Applicable temperature: -5°C ~ 40°C; • Applicable humidity: below 95%; • Applicable altitude: regions below 1,500 m (It shall be used by reducing power in regions above 1,000 m). Standard atmospheric condition •...
  • Page 19: Generator Grounding

    USING THE GENERATOR Connection of AC power WARNING All electrical equipment shall be disconnected before inserting the plug. ATTENTION • Make sure that all electrical equipment, including wires and plugs, are in good condition before connecting to the generator; • Make sure that all loads driven by the generator are within rated load range; •...
  • Page 20: Service And Maintenance

    SERVICE AND MAINTENANCE Good maintenance and service is the best guarantee for safe, economical and zero-failure operation. It also contributes to environmental protection. In order to keep the generator in good condition, you must inspect and maintain it regularly. The maintenance schedule is as follows: Then every three Maintenance cycle...
  • Page 21: Spark Plug Inspection

    SERVICE AND MAINTENANCE WARNING Please shut down the engine first before performing any maintenance. The engine shall be placed in a horizontal position. In order to prevent the engine from starting up, separate spark plug cap shall be separated from spark plug. Do not use it indoors or use it in a tunnel, cave or other places ventilated poorly.
  • Page 22: Adjustment Of The Carburetor

    SERVICE AND MAINTENANCE Install the spark plugs in reverse order of removal. Spark cold torque: 22.5±2.5 N.m Tip: If there is no torque wrench when installing the spark plug, a better estimation method is to screw it 1/4-1/2 turns by force after screwing it in place, but the spark plug shall be screwed to specified torque as soon as possible. Adjustment of the carburetor The carburetor is an important components of the engine.
  • Page 23: Air Filter

    SERVICE AND MAINTENANCE Unscrew oil dipstick; Refill oil to a proper level, tighten oil dipstick, cover external cover plate and tighten the knob. Recommended oil: SAE S10W/30 Oil grade: API standard Model SJ or higher Volume: 0.3gal Air filter Dirty air cleaner may prevent air from flowing into the carburetor. In order to prevent failure of the carburetor, please maintain air cleaner regularly.
  • Page 24: Fuel Filter Screen

    SERVICE AND MAINTENANCE Fuel filter screen WARNING Be sure not to open fuel tank of the generator in a place where smoking or with flame. 1. Remove fuel tank cap and fuel tank filter screen. 2. Clean fuel tank filter screen with gasoline. 3.
  • Page 25: Storage And Transport

    STORAGE AND TRANSPORT Generator storage If it is stored long-term, in order to prevent aging, you shall take some storage measures. Shut down generator. Open fuel tank cap, to take out fuel filter screen. Pump all fuel in fuel tank into special fuel tank, and then reassemble fuel tank cap back.
  • Page 26: Generator Transport

    STORAGE AND TRANSPORT Gently pull startup handle until you feel resistance, allowing both inlet valve and exhaust valve to be closed. Disconnect the battery cable. Place the generator set in a clean and dry area. Generator transport • When the generator set is transported, it shall be ensured that there is no fuel spilling; •...
  • Page 27: Troubleshooting

    TROUBLESHOOTING...
  • Page 28 TROUBLESHOOTING...
  • Page 29: Technical Parameters

    TECHNICAL PARAMETERS Item GM9000iE GM9000iED/GM9000iEDC Rated Power (kW) 7.6(GAS.)/7.2(LPG) Max. Power (kW) 9.0(GAS.)/8.55(LPG) 460i 460i Engine Model 92x69 92x69 Stroke x Bore (mm) Engine Type 4-stroke 4-stroke Displacement (cc) Gas Distribution Mode Cooling Mode Forced cooling wind Rated Speed (RPM)
  • Page 30: Circuit Diagram

    CIRCUIT DIAGRAM GM9000iE SCHEMATICS...
  • Page 31 CIRCUIT DIAGRAM GM9000iED/GM9000iEDC SCHEMATICS...
  • Page 32: Choosinga Generator

    CHOOSING A GENERATOR...
  • Page 33 In production management, based on orderly, efficient, scientific principles. trying to do as better as possible in product design, development, production, inspection,etc. to make our production can keep orderly . And will continue to make improvement to make sure that keep the competitiveness.