GENMAX GENERATOR INVERTER GENERATOR USER'S MANUAL GM2800iSAC GM4000iSAPC Portable Inverter Generator Portable Inverter Generator 2300 Running Watts | 2800 Peak Watts 3200 Running Watts | 4000 Peak Watts WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety. Operation, maintenance and storage of this product.
Page 2
DISCLAIMERS: All information, illustrations and specifications in this manual are based on the latest information available at the time of publishing. The illustrations used in this manual are intended as representative reference views only. Moreover, because of our continuous product improvement policy, we may modify information, illustrations and/or specifications to explain and/or exemplify a product, service or maintenance improvement.
Page 3
DESCRIPTION OF FITTINGS Spark Plug Socket Wrench Dual-Purpose Screwdriver Funnel Phillips and slot blade Used in spark plug maintenance, screwdriver used for generator It's used to oil the generator. inspection, and installation. maintenance. 30A 120V L5-30P to TT-30R Plug Adapter Change the 30A 120V L5-30R socket to the TT-30R socket.
2. WHO GIVES THIS WARRANTY (WARRANTOR): CHONGQING DINKING POWER MACHINERY CO., LTD 3. WHO RECEIVES THIS WARRANTY(PURCHASER):The original purchaser (other than for purposes of resale) of the Genmax's inverter. 4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any portable generator supplied or manufactured by Warrantor.
TABLE OF CONTENTS LIMITED WARRANTY SAFETY WARNING SAFETY INSTRUCTIONS NAMES OF COMPONENTS CONTROL FUNCTIONS PREPARATIONS 1.Fuel............................12 2.Oil...............................12 3.Pre-operation inspection......................13 STARTING UP THE GENERATOR SHUTTING DOWN THE GENERATOR USING THE GENERATOR 1.Service environment of the generator..................16 2.Generator wiring........................16 3.Generator grounding.........................17 4.Parallel operation........................18 SERVICE AND MAINTENANCE 1.Spark plug inspection.......................20 2.Adjustment of the carburetor.....................21...
SAFETY WARNING Personal and property safeties of you and others are very vital. Please read the Safety Warning in the User's Manual and the decals of the generator set carefully.The Safety Warning can alert you to those potential hazards that could harm you and others. In front of each Safety Warning, there is one of four words "DANGER"...
SAFETY INSTRUCTIONS Before operating the generator, it will help you avoid accidents to read and understand the Manual and familiarize yourself with the safe operation procedures of the generator. Please do not use in humid Please do not use indoors environment Please do not connect it to Please do not smoke when refueling...
Page 8
SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS...
NAMES OF COMPONENTS ① Fuel Tank Cap: Open the fuel tank cap and fill with ⑧ Muffler: Avoid contact until the engine is cooled proper amount of gasoline. down. The spark arrestor prevents sparks from exiting the muffler. It must be removed for servicing. ②...
⑤ CO Alarm: Flashing red light: dangerous levels of GM6000SPK sold by GENMAX. The connector sockets carbon monoxide gas have built up leave immediately is only used to connect two inverter generators. They until area has aired out.
Page 11
Ground Terminal: The ground terminal is used to connect the two same type generators with special externally ground the inverter. parallel kit GM6000SPK sold by GENMAX. The connector sockets is only used to connect two inverter ③ CO Alarm: Flashing red light: dangerous levels of generators.
Page 12
CONTROL FUNCTIONS DIGITAL DISPLAY CENTER AUTOMATIC ROTATING DIGITAL DISPLAY(scroll once every 3 s) ① OVERLOAD: Red light means the machine ⑥ VOLTAGE: Voltage display. overload. ⑦ FREQUENCY: Frequency display. ② POWER: Indicates the inverter is ready to be used. ⑧ TIME: Represents total operation time of the ③...
PREPARATIONS Fuel DANGER • Fuel is flammable and toxic, please read the Safety Instruction carefully before refueling; • Do not fuel too full, otherwise fuel will spill after fuel tank is warmed; • After refueling, confirm that the fuel tank cap has been tightened. ATTENTION •...
PREPARATIONS Pre-use Inspection WARNING Even if the generator is not in service, its important component may suddenly fails. Before the generator is started up, if any of following components is unable to work properly, please inspect and repair carefully. Tip: The condition of the generator shall be inspected before using every time. Pre-operation inspection Fuel •...
STARTING UP THE GENERATOR Remove the load from all output ends; Switch low idle switch to "OFF"; Turn multi-switch to "CHOKE" position; Tip: When hot engine is started up, it is unnecessary to close the choke valve, but turn the combination switch to "RUN". First gently pull startup handle, until guy cable is hooked tight, and then pull it with effort.
USING THE GENERATOR Service environment of the generator • Applicable temperature: -5°C ~ 40°C; • Applicable humidity: below 95%; • Applicable altitude: regions below 1,500 m (It shall be used by reducing power in regions above 1,000 m). Standard atmospheric condition •...
USING THE GENERATOR Connection of AC power WARNING All electrical equipment shall be disconnected before inserting the plug. ATTENTION • Make sure that all electrical equipment, including wires and plugs, are in good condition before connecting to the generator; • Make sure that all loads driven by the generator are within rated load range; •...
USING THE GENERATOR Parallel operation The parallel connection ports allow you to connect two generators to increase the total available electrical power. Follow the instructions included with your parallel connection kit for proper installation and operation. Parallel Connectors (120V OUTPUT): To increase AC power output, Connectors (Red) the connector sockets are used to connect the two same type Connectors (Black)
SERVICE AND MAINTENANCE Good maintenance and service is the best guarantee for safe, economical and zero-failure operation. It also contributes to environmental protection. In order to keep the generator in good condition, you must inspect and maintain it regularly. The maintenance schedule is as follows: Then every three Maintenance cycle...
SERVICE AND MAINTENANCE WARNING Please shut down the engine first before performing any maintenance. The engine shall be placed in a horizontal position. In order to prevent the engine from starting up, separate spark plug cap shall be separated from spark plug. Do not use it indoors or use it in a tunnel, cave or other places ventilated poorly.
SERVICE AND MAINTENANCE Install the spark plugs in reverse order of removal. Spark cold torque: 14±1N.m(123.9±8.8in-lb) Tip: If there is no torque wrench when installing the spark plug, a better estimation method is to screw it 1/4-1/2 turns by force after screwing it in place, but the spark plug shall be screwed to specified torque as soon as possible. Adjustment of the carburetor The carburetor is an important components of the engine.
SERVICE AND MAINTENANCE Place an oil pan under the engine, tilt the generator to quickly pour out oil; After discharging the oil, put the generator back on level ground; Fill the oil to the appropriate level, tighten the dipstick, cover the outer cover, and tighten the Don't go over the scale bolts.
SERVICE AND MAINTENANCE 1. Reassemble empty air cleaner cap back to original position, and tighten screws; 2. Assemble the right outer cover and tighten the bolts. Fuel filter screen WARNING Be sure not to open fuel tank of the generator in a place where smoking or with flame. 1.
STORAGE AND TRANSPORT Generator storage If it is stored long-term, in order to prevent aging, you shall take some storage measures. Shut down generator. Open fuel tank cap, to take out fuel filter screen. Pump all fuel in fuel tank into special fuel tank, and then reassemble fuel tank cap back.
STORAGE AND TRANSPORT Gently pull startup handle until you feel resistance, allowing both inlet valve and exhaust valve to be closed. Place the generator set in a clean and dry area. Generator transport • When the generator set is transported, it shall be ensured that there is no fuel spilling; •...