Key Fig. 12
AL
Alarm device
AUX
Auxiliary output
Lead connection
Dbr
Reset button (info button)
(EK1)
/reset
EK2
Remote reset button
FSV
Flame signal amplifier
ION
Ionisation probe
K...
Relay contact
Warning lamp with 3 colours
LED
LP
Air pressure switch
LR
Load controller
LR-OPEN
Load controller OPEN
LR-CLOSE
Load controller CLOSED
M
Fan motor
NT
Power supply unit
P LT
Pressure switch valve test
Max. pressure switch
Pmax
Pmin
Min. pressure switch
POC
Closure test
Pilot valve
PV
QRA...
UV flame detector
R
Control thermostat or pressure switch
SA
Actuator
SA-KL
Low flame actuator
SA-NL
High flame actuator
SA-R
Feedback actuator
SA-Z
Actuator CLOSED
Ignition load actuator
SA-ZL
SL
Safety loop
STB
Safety limit thermostat
SV
Safety valve
V1
Fuel valve
V2
Fuel valve
V2a
Fuel valve
W
Limit pressure switch or thermostat
Ignition transformer
Z
µC
µC controller
Input/output 1 signal (ON)
Input/output 2 signal (ON)
Input 1 permitted signal (ON) or 0 (OFF)
Technical description of the burner
Tab. H
19
GB
Times
TSA
Safety time
tw
Waiting time
t1
Pre-purge time
t3
Pre-ignition time
t3n
Post-ignition time (P257 +0.3 seconds)
Ignition time
6s
6÷12s
>12s
t4
Interval: end of safety time load controller
release
t8
Post-purge time
t10
Specified time air pressure switch state mes-
sage (time out)
t11
Opening time of actuator (time out)
t12
Closing time of actuator (time out)
pilot valve ON - fuel valve OFF
pilot valve ON - fuel valve ON
pilot valve OFF - fuel valve ON
Tab. I
20160576