4. Failure cause and measures
4.1.2 Emergency Display
When any trouble takes place during operation, this displays and it stops as an emergency stop.
When any abnormality happens, a trouble code lamp flickers. In this time when trouble code switch
is pressed, a failure code will be digital monitor.
Item
DISCHARGE TEMP.
H
WATER TEMP.H
ENG. OIL PRESS.
DISCHARGE TEMP.
SENSOR
WATER TEMP.
SENSOR
CRARK CASE
PRESS.
Digital monitor
Failure
code
Lamp displays when the discharge air
E-1
temperature at the outlet of the compressor
air-end reaches 248°F (120℃).
Lamp displays when engine coolant
E-2
temperature reaches 210°F(99℃).
Lamp goes on when engine oil pressure
E-3
drops.
[The function pressure : 14psi(0.98bar)]
Discharge air temperature sensor of the
E-6
discharge air outlet disconnected.
It is displayed when engine coolant
E-7
temperature sensor is disconnected.
It is displayed when the internal pressure of
the crank case rises.
E-9
[The function pressure:
1.0±0.3psi(0.069±0.02bar)]
ERROR CODE switch
Contents
ERROR CODE lamp
EMERGENCY code
4-2
Measures
See 4.2
"Troubleshooting"
CONTROL POWER switch