Hokuetsu AIRMAN PDS185S-6EZ1 Instruction Manual page 23

Engine compressor
Table of Contents

Advertisement

3.3.5 Check fuel
Red lamp
Do not fill fuel up to the filler level.
When the fuel tank is filled up to the filler level, the expansion volume of the tank is too small and
may lead to problems with fuel flow and containment. Furthermore, fuel may spill from the fuel
tank due to vibration caused during movement or transportation of the unit.
D004
3.3.6 Drain fuel tank condensate
B
A
CLOSE OPEN
3. Operation
Green lamp
A170655E
Do not, under any circumstance, bring lit cigarettes and/or matches near fuel.
The fuel is extremely flammable and dangerous. Be aware of fire sources
that can easily ignite the fuel.
Refuel only after stopping the engine, and never leave open fuel cans near
the machine. Do not spill. It is a fire hazard. When spills occur, wipe up
thoroughly.
Never use alcohol-base cleaning fluid. If it sticks to such parts made of
plastic, it causes degradation of liquid surface visibility, and in worst case, it
leads to crack and fuel leak due to crack caused.
A130970
Before starting operation, make sure to check the level
of residual fuel so that fuel shortage during operation
can be avoided. Drain condensate accumulated at the
bottom of fuel tank whenever necessary.
Refueling should be done outdoors or in a
well-ventilated place. Lamp is ON according to fuel
level when CONTROL POWER switch of instrument
panel is set to
when fuel level is about 1/3 or less of maximum
level. Only one red lamp blinks when fuel level
becomes more less. Replenish fuel quickly when
lamp is ON as red.
Gradually open the drain valve [B] on the left side
the fuel tank [A] , drain the condensate from the
tank.
When all the condensate is drained away and the
fuel starts to come out, firmly shut the drain valve
[B].
Drain the condensate in container, and then dispose
of condensate according to the designated
regulations.
3-7
position. Two red lamps are ON

Advertisement